Evidence map›Paper›PMID 30057524›Full record

ArticleFrontiers in neuroscience2018

A Prototype of a Neural, Powered, Transtibial Prosthesis for the Cat: Benchtop Characterization.

Hangue Park, Muhammad S Islam, Martha A Grover, Alexander N Klishko, Boris I Prilutsky, Stephen P DeWeerth

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Hangue ParkSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, United States.
Muhammad S IslamWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, United States.
Martha A GroverSchool of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, United States.
Alexander N KlishkoBiomechanics and Motor Control Laboratory, School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, United States.
Boris I PrilutskyBiomechanics and Motor Control Laboratory, School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, United States.
Stephen P DeWeerthSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, United States.
Georgia Institute of Technology · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We developed a prototype of a neural, powered, transtibial prosthesis for the use in a feline model of prosthetic gait. The prosthesis was designed for attachment to a percutaneous porous titanium implant integrated with bone, skin, and residual nerves and muscles. In the benchtop testing, the prosthesis was fixed in a testing rig and subjected to rhythmic vertical displacements and interactions with the ground at a cadence corresponding to cat walking. Several prosthesis functions were evaluated. They included sensing ground contact, control of transitions between the finite states of prosthesis loading, and a closed-loop modulation of the linear actuator gain in each loading cycle. The prosthetic design parameters (prosthesis length = 55 mm, mass = 63 g, peak extension moment = 1 Nm) corresponded closely to those of the cat foot-ankle with distal shank and the peak ankle extension moment during level walking. The linear actuator operated the prosthetic ankle joint using inputs emulating myoelectric activity of residual muscles. The linear actuator gain was modulated in each cycle to minimize the difference between the peak of ground reaction forces (GRF) recorded by a ground force sensor and a target force value. The benchtop test results demonstrated a close agreement between the GRF peaks and patterns produced by the prosthesis and by cats during level walking.

Indexed as

bone-anchored transtibial prosthesiscatclosed-loop controlground reaction forcesensing and powered prosthesis

Identifiers

PMID30057524
PMCPMC6053514
OpenAlexW2810817700

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked