Evidence map›Paper›PMID 30056564›Full record

ArticlePediatric radiology2018

Iterative algorithms for metal artifact reduction in children with orthopedic prostheses: preliminary results.

Seema Toso, Meryle Laurent, Elise Dupuis Lozeron, Pauline Brindel, Marirosa Cristallo Lacalamita, Sylviane Hanquinet

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Seema TosoPaediatric Radiology Unit, Division of Radiology, Geneva Children's Hospitals, Rue Willy-Donzé 6, 1211, Geneva, Switzerland. seema.toso@hcuge.ch.ORCID http://orcid.org/0000-0003-1502-8877
Meryle LaurentPaediatric Radiology Unit, Division of Radiology, Geneva Children's Hospitals, Rue Willy-Donzé 6, 1211, Geneva, Switzerland.
Elise Dupuis LozeronDivision of Clinical Epidemiology, Geneva University Hospitals, Geneva, Switzerland.
Pauline BrindelDivision of Clinical Epidemiology, Geneva University Hospitals, Geneva, Switzerland.
Marirosa Cristallo LacalamitaPaediatric Radiology Unit, Division of Radiology, Geneva Children's Hospitals, Rue Willy-Donzé 6, 1211, Geneva, Switzerland.
Sylviane HanquinetPaediatric Radiology Unit, Division of Radiology, Geneva Children's Hospitals, Rue Willy-Donzé 6, 1211, Geneva, Switzerland.
University Hospital of Geneva · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIncreased computational power allows computed tomography (CT) software to process very advanced mathematical algorithms to generate better quality images at lower doses. One such algorithm, iterative metal artifact reduction (iMAR) has proven to decrease metal artifacts seen in CT images of adults with orthopedic implants.

objectivesTo evaluate artifact reduction capability of the algorithm in lower-dose pediatric CT compared to our routine third-generation advanced modeled iterative reconstruction (ADMIRE) algorithm. MATERIALS AND

methodsThirteen children (11-17 years old) with metal implants underwent routine clinically indicated CT. Data sets were reconstructed with an iMAR algorithm. Hounsfield units and image noise were measured in bone, muscle and fat in the streak artifact (near the implant) and at the greatest distance from the artifact (far from the implant). A regression model compared the effects of the algorithm (standard ADMIRE vs. iMAR) near and far from the implant.

resultsNear the implant, Hounsfield units with iMAR were significantly different in our standard ADMIRE vs. iMAR for bone, muscle and fat (P<0.001). Noise was significantly different in standard ADMIRE vs. iMAR in bone (P<0.003). Far from the implant, Hounsfield units and noise were not significantly different for ADMIRE vs. iMAR, for the three tissue types.

conclusionThese preliminary results demonstrate that iMAR algorithms improves Hounsfield units near the implant and decreases image noise in bone in low-dose pediatric CT. It does this without changing baseline tissue density or noise far from the implant.

Indexed as

AlgorithmsArtifactsInternal FixatorsJoint ProsthesisAdolescentChildHumansMetalsPostoperative ComplicationsRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesTomography, X-Ray ComputedMetalsArtifact reductionChildrenComputed tomographyIterative reconstructionMetal artifact reductionMetal implant

Identifiers

PMID30056564
OpenAlexW2883648559

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.