Evidence map›Paper›PMID 30054509›Full record

ArticleScientific reports2018

Utilization of 3D printing technology to facilitate and standardize soft tissue testing.

Mario Scholze, Aqeeda Singh, Pamela F Lozano, Benjamin Ondruschka, Maziar Ramezani, Michael Werner, Niels Hammer

Abstract read
In one paragraph

Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. How Strong Is the Ligamentum Teres of the Hip? A Biomechanical Analysis.Clinical orthopaedics and related research · 2024
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Tensile fatigue strength and endurance limit of human meniscus.Journal of the mechanical behavior of biomedical materials · 2022
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mario ScholzeDepartment of Anatomy, University of Otago, New Zealand Department of Anatomy, Dunedin, New Zealand. mario.scholze@mb.tu-chemnitz.de.
Aqeeda SinghDepartment of Anatomy, University of Otago, New Zealand Department of Anatomy, Dunedin, New Zealand.ORCID 0000-0001-5685-0635
Pamela F LozanoDepartment of Anatomy, University of Otago, New Zealand Department of Anatomy, Dunedin, New Zealand.
Benjamin OndruschkaInstitute of Legal Medicine, Medical Faculty University of Leipzig, Leipzig, Germany.
Maziar RamezaniDepartment of Mechanical Engineering, Auckland University of Technology, Auckland, New Zealand.
Michael WernerDepartment of Trauma, Orthopedic and Plastic Surgery, University Hospital of Leipzig, Leipzig, Germany.
Niels HammerDepartment of Anatomy, University of Otago, New Zealand Department of Anatomy, Dunedin, New Zealand. nlshammer@googlemail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three-dimensional (3D) printing has become broadly available and can be utilized to customize clamping mechanisms in biomechanical experiments. This report will describe our experience using 3D printed clamps to mount soft tissues from different anatomical regions. The feasibility and potential limitations of the technology will be discussed. Tissues were sourced in a fresh condition, including human skin, ligaments and tendons. Standardized clamps and fixtures were 3D printed and used to mount specimens. In quasi-static tensile tests combined with digital image correlation and fatigue trials we characterized the applicability of the clamping technique. Scanning electron microscopy was utilized to evaluate the specimens to assess the integrity of the extracellular matrix following the mechanical tests. 3D printed clamps showed no signs of clamping-related failure during the quasi-static tests, and intact extracellular matrix was found in the clamping area, at the transition clamping area and the central area from where the strain data was obtained. In the fatigue tests, material slippage was low, allowing for cyclic tests beyond 10

Indexed as

Printing, Three-DimensionalBiomechanical PhenomenaCollagenHumansImage Processing, Computer-AssistedKeratinsLigamentsMaterials TestingReference StandardsSkullSterilizationStress, MechanicalTendonsTissue EngineeringCollagenKeratins

Identifiers

PMID30054509
PMCPMC6063914

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.