ArticleBMC musculoskeletal disorders2018
Objective quantification of ligament balancing using VERASENSE in measured resection and modified gap balance total knee arthroplasty.
Article in BMC musculoskeletal disorders, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04251442 (Randomized Controlled Trial of Patients Undergoing a Total Knee Arthroplasty With and Without the Use of Intraoperative Sensing Technology), which is not on this map. Cited by 28 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Randomized Controlled Trial of Patients Undergoing a Total Knee Arthroplasty With and Without the Use of Intraoperative Sensing Technology
Who cites it
28 citing papers in PubMed, 2 syntheses or guidelines pooled it, 60 citations in OpenAlex.
- Verasense sensor-assisted total knee arthroplasty showed no difference in range of motion, reoperation rate or functional outcomes when compared to manually balanced total knee arthroplasty: a systematic review.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Pooled it
- Current role of intraoperative sensing technology in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2021Pooled it
- Intraoperative pressure sensors improve soft-tissue balance but not clinical outcomes in total knee arthroplasty: a multicentre randomized controlled trial.The bone & joint journal · 2022Trial
- Postoperative outcomes after conventional, robotic-arm-assisted, and pressure-sensor-guided cruciate-retaining total knee arthroplasty: a retrospective cohort study.Journal of robotic surgery · 2026Article
- Inter- and Intra-Rater Reliability of Pre-Resection Ligament Tension Assessment Using a Digital Tensioner in Imageless Robotic-Assisted Total Knee Replacement.Orthopaedic surgery · 2026Article
- Alignment and/or ligament balancing? Towards truly personalized total knee arthroplasty-A narrative review.Journal of experimental orthopaedics · 2026Review
- Inverse Kinematic Alignment in Robot-Assisted Total Knee Arthroplasty: A Simplified Surgical Technique.Arthroplasty today · 2025Article
- Biosensor-Integrated Tibial Components in Total Knee Arthroplasty: A Narrative Review of Innovations, Challenges, and Translational Frontiers.Bioengineering (Basel, Switzerland) · 2025Review
- Muscle-Driven Total Knee Replacement Stability with Virtual Ligaments.Bioengineering (Basel, Switzerland) · 2025Article
- [Trends in navigation-handheld systems].Orthopadie (Heidelberg, Germany) · 2024Review
- Incidence of soft tissue releases in robotic assisted cementless TKA with mechanical alignment and flexion gap balancing.Arthroplasty (London, England) · 2023Article
- "Smart Knee Implants: An Overview of Current Technologies and Future Possibilities".Indian journal of orthopaedics · 2023Review
- Patient-reported impairment following TKA is reduced when a computationally simulated predicted ideal alignment is achieved.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- [Market overview: Robotic-assisted arthroplasty : Current robotic systems, learning curve and cost analysis].Orthopadie (Heidelberg, Germany) · 2022Review
- The risk of tibial eminence avulsion fracture with bi-unicondylar knee arthroplasty : a finite element analysis.Bone & joint research · 2022Article
- Intraoperative Load Sensing in Total Knee Arthroplasty Leads to a Functional but Not Clinical Difference: A Comparative, Gait Analysis Evaluation.Journal of functional morphology and kinesiology · 2022Article
- Prostheses option in revision total knee arthroplasty, from the bench to the bedside: (1) basic science and principles.EFORT open reviews · 2022Review
- Article
- Design of an Affordable, Modular Implant Device for Soft Tissue Tension Assessment and Range of Motion Tracking During Total Hip Arthroplasty.IEEE journal of translational engineering in health and medicine · 2022Article
- Kinetic Sensors for Ligament Balance and Kinematic Evaluation in Anatomic Bi-Cruciate Stabilized Total Knee Arthroplasty.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSoft tissue balancing which is above all most important factor of total knee arthroplasty, has been performed by subjective methods. Recently objective orthosensor has been developed for compartment pressure measurement. The purpose of this study was: (1) to quantify the compartment pressure of the joint throughout the range of motion during TKA using orthosensor, (2) to determine the usefulness of orthosensor by analyzing correlation between the pressure in both compartment with initial trial and after final implantation, and (3) to evaluate the types and effectiveness of additional ligament balancing procedures to compartment pressure.
methodsEighty-four patients underwent total knee arthroplasty (TKA) using VERASENSE Knee System. TKA was performed by measured resection and modified gap balance technique. Compartment pressure was recorded on full extension, 30°, 60°, 90° and full flexion at initial (INI), after each additional procedure, and after final (FIN) implantation. "Balanced" knees were defined as when the compartment pressure difference was less than 15 pounds.
resultsThirty patients (35.7%) showed balanced knee initially and 79 patients (94.0%) showed balance after final implantation. The proportion of balanced knee after initial bony resection, modified gap balancing TKAs showed significantly higher proportion than measured resection TKAs (P = 0.004) On both compartment, the pressure was generally decreased throughout the range of motion. Linear correlation on both compartment showed statistically significant throughout the range on motion, with higher correlation value on the lateral compartment. Total 66 additional ligament balancing procedures were performed.
conclusionUsing orthosensor, we could obtain 94% quantified balance knee, consequently. And between the techniques, measured resection TKA showed less balanced knee and also required more additional procedures compared to modified gap balancing TKA. Furthermore, with the acquired quantified data during appropriate ligament balancing, the surgeon could eventually reduce the complications associated with soft tissue imbalance in the future.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.