Evidence map›Paper›PMID 30053071›Full record

ArticleJournal of radiation research2018

Radiation therapy for deep periocular cancer treatments when protons are unavailable: is combining electrons and orthovoltage therapy beneficial?

Kevin Martell, Yannick Poirier, Tiezhi Zhang, Alana Hudson, David Spencer, Ferenc Jacso, Richard Hayashi, Robyn Banerjee, Rao Khan, Nathan Wolfe and 1 more

Abstract read
In one paragraph

Article in Journal of radiation research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kevin MartellDepartment of Oncology, University of Calgary, Tom Baker Cancer Centre 1331 29 Street Northwest, Calgary, Alberta, Canada.
Yannick PoirierDepartment of Radiation Oncology, University of Maryland, 22 S Greene St, Baltimore, MD, USA.
Tiezhi ZhangDepartment of Radiation Oncology, Washington University in St. Louis, 660 S. Euclid Ave., CB, St. Louis, MO, USA.
Alana HudsonDepartment of Oncology, University of Calgary, Tom Baker Cancer Centre 1331 29 Street Northwest, Calgary, Alberta, Canada.
David SpencerDepartment of Oncology, University of Calgary, Tom Baker Cancer Centre 1331 29 Street Northwest, Calgary, Alberta, Canada.
Ferenc JacsoDepartment of Oncology, University of Calgary, Tom Baker Cancer Centre 1331 29 Street Northwest, Calgary, Alberta, Canada.
Richard HayashiCalgary Zone, Alberta Health Services, Foothills Medical Centre, 1331-29 ST NW, Calgary, Alberta, Canada.
Robyn BanerjeeDepartment of Oncology, University of Calgary, Tom Baker Cancer Centre 1331 29 Street Northwest, Calgary, Alberta, Canada.
Rao KhanDepartment of Radiation Oncology, Washington University in St. Louis, 660 S. Euclid Ave., CB, St. Louis, MO, USA.
Nathan WolfeCalgary Zone, Alberta Health Services, Foothills Medical Centre, 1331-29 ST NW, Calgary, Alberta, Canada.
Jon-Paul VoroneyDepartment of Oncology, University of Calgary, Tom Baker Cancer Centre 1331 29 Street Northwest, Calgary, Alberta, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Deep periocular cancers can be difficult to plan and treat with radiation, given the difficulties in apposing bolus to skin, and the proximity to the retina and other optic structures. We sought to compare the combination of electrons and orthovoltage therapy (OBE) with existing modalities for these lesions. Four cases-a retro-orbital melanoma (Case 1) and basal cell carcinomas, extending across the eyelid (Case 2) or along the medial canthus (Cases 3-4)-were selected for comparison. In each case, radiotherapy plans for electron only, 70% electron and 30% orthovoltage (OBE), volumetric-modulated arc therapy (VMAT), conformal arc, and protons were compared. Dose-volume histograms for planning target volume coverage and selected organs at risk (OARs) were then calculated. The V90% coverage of the planning target volume was >98% for electrons, VMAT, conformal arc and proton plans and 90.2% and 89.5% in OBE plans for Cases 2 and 3, respectively. The retinal V80% was >98% in electron, VMAT and proton plans and 79.4%; and 87.1% in OBE and conformal arcs for Case 2 and 91.3%, 36.4%, 56.9%, 52.4% and 43.7% for Case 3 in electrons, OBE, VMAT, conformal arc and proton plans, respectively. Protons provided superior coverage, homogeneity and OAR sparing, compared with all other modalities. However, given its simplicity and widespread availability, OBE is a potential alternative treatment option for moderately deep lesions where bolus placement is difficult.

Indexed as

AlgorithmsBasal Cell CarcinomaElectronsEyelid NeoplasmsHumansMelanomaOrgans at RiskProtonsRadiometryRadiotherapyRadiotherapy, ConformalRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedX-RaysProtons

Identifiers

PMID30053071
PMCPMC6151628

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.