ArticleSensors (Basel, Switzerland)2018
Field Applications of Ultra High Frequency Techniques for Defect Detection in GIS.
Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The Denoising Method for Transformer Partial Discharge Based on the Whale VMD Algorithm Combined with Adaptive Filtering and Wavelet Thresholding.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The reliable and stable operation of power apparatus is important for the development of GIS. It is important to utilize condition monitoring technologies and anticipate possible failures in advance. Many papers have been published about the partial discharge detection with UHF or X-ray in laboratory, but seldom in field application. Thus, many engineers at project sites are not familiar with the current professional diagnosis techniques. Recently, during the GIS routine data analysis obtained by partial discharge online monitoring system, it was found that the UHF monitoring signals' developing trend of the 220 kV GIS No. 2 high-voltage side of transformer in phase C at an actual station was abnormal and needed further detection. In order to precisely investigate the problem and then guide the operation and maintenance activities, a series of professional diagnoses were conducted. Three new types of partial discharge detection and positioning methods were applied for accuracy, including UHF partial discharge detection based on multi-stage amplified signal demodulation and multiple weighted averages processing; the partial discharge detection based on the signal radiation hole of insulation disk at the ground connection; and the positioning method based on UHF-SHF. After a series of troubleshooting works, the partial discharge defects have been diagnosed, and the case can be referred in the field monitoring of GIS.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.