Evidence map›Paper›PMID 30046305›Full record

ArticleAnesthesiology research and practice2018

Objective Evaluation of a New Epidural Simulator by the CompuFlo

Giorgio Capogna, Alessandra Coccoluto, Emanuele Capogna, Angelica Del Vecchio

2 registry-linked trialsAbstract read
In one paragraph

Article in Anesthesiology research and practice, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03625232 completednot on this mapstarted 2019, after this paper: background citation

Multi-Center Post-Marketing Study Protocol: (MC-PMS) A Single-arm Open Label Observational Study to Further Document the Safety and Effectiveness of the Epidural Space Verification With the CompuFlo® Epidural Computer Controlled System

TypeobservationalSponsorEuropean e-Learning School in Obstetric AnesthesiaRan2019 to 2019Enrolled250ConditionsEpidural, AnesthesiaArmsCompuFlo® Epidural Computer Controlled System
NCT04205773 completednot on this mapstarted 2019, after this paper: background citation

Confirmation of Epidural Catheter Location by Epidural Pressure Waveform Recordings by the CompuFlo Epidural Instrument

TypeobservationalSponsorEuropean e-Learning School in Obstetric AnesthesiaRan2019 to 2019Enrolled30ConditionsAnesthesia, LocalArmsCompuFlo
3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Giorgio CapognaEuropean School of Obstetric Anesthesia (EESOA), Maternal Neonatal Simulation Centre, Roma, Italy.ORCID 0000-0003-2298-8905
Alessandra CoccolutoEuropean School of Obstetric Anesthesia (EESOA), Maternal Neonatal Simulation Centre, Roma, Italy.
Emanuele CapognaEuropean School of Obstetric Anesthesia (EESOA), Maternal Neonatal Simulation Centre, Roma, Italy.
Angelica Del VecchioEuropean School of Obstetric Anesthesia (EESOA), Maternal Neonatal Simulation Centre, Roma, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn this study, we describe a custom-made new epidural simulator, created by modifying the inner structure of a commercially available one, in the attempt to make it adequately realistic. To validate and evaluate the realism of our device, we used the Computerized Epidural Instrument CompuFlo.

methodThe Compuflo CompuFlo curves obtained from 64 experiments on the epidural simulator were compared to 64 curves obtained from a previous human study, from consecutive laboring parturients requesting epidural analgesia.

resultsEpidural simulator and human pressure curves were very similar. There was a significant difference between the drop of pressure due to false and true loss of resistance (LOR) in both the groups. DISCUSSION: Our simulator can realistically reproduce the anatomical layers the needle must pass as demonstrated by the similarity between the simulator and human pressure curves and the small differences of pressure values recorded. CompuFlo may be used as an objective tool to create and assess and compare objectively the epidural task trainers.

Identifiers

PMID30046305
PMCPMC6038690

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials