Evidence map›Paper›PMID 30045306›Full record

ArticleMedicine2018

Comparison between three-dimensional CT and conventional radiography in proximal tibia morphology.

Yijie Zhang, Yanxi Chen, Minfei Qiang, Kun Zhang, Haobo Li, Yuchen Jiang, Xiaoyang Jia

Abstract readComparative Study
In one paragraph

Article in Medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yijie ZhangDepartment of Orthopaedic Trauma, East Hospital, Tongji University School of Medicine, Shanhai, China.
Yanxi Chen
Minfei Qiang
Kun Zhang
Haobo Li
Yuchen Jiang
Xiaoyang Jia

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To provide morphological parameters of the normal tibial plateau by using three-dimensional (3D) CT and conventional radiography.We performed morphological measurements of tibial plateau on 157 consecutive adults using radiographic and 3D computed tomography (CT). Gender differences as well as differences in measurement techniques were statistically compared. Intraclass correlation coefficient (ICC) was used to evaluate intra- and interobserver reproducibility.The mediolateral dimensions, anteroposterior dimensions of tibial plateau showed significant differences according to gender, but no statistical differences were observed in coronal tibial slope as well as in posterior slope. There were significant differences in all parameters between 2 measurement techniques. 3D-CT measurements had a higher ICC in all parameters than that in the radiographs.This study confirmed that 3D morphological measurements of tibial plateau have more reproducibility than radiographs. Our data will be helpful for tibial component design and placement.

Indexed as

AdultAgedAnthropometryFemaleHumansImaging, Three-DimensionalMaleMiddle AgedObserver VariationRadiographyReproducibility of ResultsStatistics, NonparametricTibiaTomography, X-Ray Computed

Identifiers

PMID30045306
PMCPMC6078714

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked