ArticleJournal of microscopy2018
Label-free high-speed wide-field imaging of single microtubules using interference reflection microscopy.
Article in Journal of microscopy, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 43 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
43 citing papers in PubMed.
- Microtubule posttranslational modifications provide unique recognition patterns for associated proteins.The EMBO journal · 2026Article
- Oxidative stress impairs processive motility of the axonal transport motor KIF1A.The Journal of biological chemistry · 2026Article
- Dimeric Cin8 motors have an inherent plus-end bias and weak interhead coordination.Biophysical journal · 2026Article
- A nucleotide code governs Lis1's ability to relieve dynein autoinhibition.Nature chemical biology · 2026Article
- Dimeric Cin8 motors have an inherent plus-end bias and weak inter-head coordination.bioRxiv : the preprint server for biology · 2025Article
- Mechanistic insights into TTLL11 polyglutamylase-mediated primary tubulin chain elongation.Science advances · 2025Article
- The mechanochemical cycle of reactive full-length human dynein 1.Nature structural & molecular biology · 2025Article
- Physical effects of crowdant size and concentration on collective microtubule polymerization.Biophysical journal · 2025Article
- Multi-camera Simultaneous Total Internal Reflection and Interference Reflection Microscopy.bioRxiv : the preprint server for biology · 2024Article
- Lignin impairs Cel7A degradation of in vitro lignified cellulose by impeding enzyme movement and not by acting as a sink.Biotechnology for biofuels and bioproducts · 2024Article
- Colorful 3D Reconstruction and an Extended Depth of Field for a Monocular Biological Microscope Using an Electrically Tunable Lens.Biomimetics (Basel, Switzerland) · 2024Article
- Zn2+ decoration of microtubules arrests axonal transport and displaces tau, doublecortin, and MAP2C.The Journal of cell biology · 2023Article
- Herding of proteins by the ends of shrinking polymers.Physical review. E · 2023Article
- Tubulin polyglutamylation differentially regulates microtubule-interacting proteins.The EMBO journal · 2023Article
- Dynamic microtubules slow down during their shrinkage phase.Biophysical journal · 2023Article
- A Quick and Reproducible Silanization Method by Using Plasma Activation for Hydrophobicity-Based Kinesin Single Molecule Fluorescence-Microscopy Assays.Chemistry (Weinheim an der Bergstrasse, Germany) · 2022Article
- The force required to remove tubulin from the microtubule lattice by pulling on its α-tubulin C-terminal tail.Nature communications · 2022Article
- Article
- Simultaneous Interference Reflection and Total Internal Reflection Fluorescence Microscopy for Imaging Dynamic Microtubules and Associated Proteins.Journal of visualized experiments : JoVE · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
When studying microtubules in vitro, label free imaging of single microtubules is necessary when the quantity of purified tubulin is too low for efficient fluorescent labelling or there is concern that labelling will disrupt function. Commonly used techniques for observing unlabelled microtubules, such as video enhanced differential interference contrast, dark-field and more recently laser-based interferometric scattering microscopy, suffer from a number of drawbacks. The contrast of differential interference contrast images depends on the orientation of the microtubules, dark-field is highly sensitive to impurities and optical misalignments. In addition, all of these techniques require costly optical components such as Nomarski prisms, dark-field condensers, lasers and laser scanners. Here we show that single microtubules can be imaged at high speed and with high contrast using interference reflection microscopy without the aforementioned drawbacks. Interference reflection microscopy is simple to implement, requiring only the incorporation of a 50/50 mirror instead of a dichroic in a fluorescence microscope, and with appropriate microscope settings has a similar signal-to-noise ratio to differential interference contrast and fluorescence. We demonstrated the utility of interference reflection microscopy by high-speed imaging and tracking of dynamic microtubules at 100 frames per second. In conclusion, the optical quality of interference reflection microscopy falls within the range of other microscope techniques, being inferior to some and superior to others, depending on the metric used and, with minimal microscope modification, can be used to study the dynamics of unlabelled microtubules. LAY DESCRIPTION: The cytoskeleton gives a cell its shape and plays a major role in its movement and division. It's also helps organise the content of cells and is the base for intracellular transport. Important components of the cytoskeleton are microtubules, which are hollow cylindrical beams (25 nm in diameter) that assemble from protein building blocks called tubulin. Deficiencies in microtubules are related to many diseases including cancer and Alzheimer. Given their important role, microtubules are heavily investigated in many laboratories. One way to study microtubules is to isolate them from cells and image them using light microscopy. Over the years a number of imaging techniques have been used. These techniques have a number of drawbacks which are addressed by ongoing efforts which this work is a part of. Here, we present a method based on light interference that produce high quality images of microtubules. The technique is cheap and easy to implement making it accessible to a wide base of researchers.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.