Evidence map›Paper›PMID 30039502›Full record

ArticleCardiovascular and interventional radiology2018

Hydrophilic Stent Coating Inhibits Platelet Adhesion on Stent Surfaces: Initial Results In Vitro.

Tim Lenz-Habijan, P Bhogal, Marcus Peters, Albrecht Bufe, Rosa Martinez Moreno, Catrin Bannewitz, Hermann Monstadt, Hans Henkes

Registry-linked trialOpen access · hybridAbstract readComparative Study
In one paragraph

Article in Cardiovascular and interventional radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06201598 (Prospective, Single-Arm, Multicenter Study to Evaluate the Effectiveness and Safety of Endovascular Treatment in Patients With Cerebral Aneurysms Using P64 and P48 Flow-Diverter Stents), which is not on this map. Cited by 48 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed, 1 pooled it
7.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06201598 recruitingnot on this mapstarted 2024, after this paper: background citation

Prospective, Single-Arm, Multicenter Study to Evaluate the Effectiveness and Safety of Endovascular Treatment in Patients With Cerebral Aneurysms Using P64 and P48 Flow-Diverter Stents

TypeobservationalSponsorHospital Universitario Central de AsturiasRan2024 to 2025Enrolled100ConditionsCerebral Aneurysm, Thromboembolic DiseaseArmsGroup 1 - Intervention 1
3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 1 synthesis or guideline pooled it, 93 citations in OpenAlex.

  1. Efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm-A systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021
    Pooled it
  2. Article
  3. Article
  4. Multicenter study of the safety and effectiveness of intracranial aneurysm treatment with the p64MW-HPC flow modulation device.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  5. Article
  6. Observational
  7. Flow diverter surface modifications for aneurysm treatment: A review of the mechanisms and data behind existing technologies.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Review
  8. Article
  9. Review
  10. Observational
  11. Article
  12. Stent-assisted coiling using the pEGASUS-HPC stent for acutely ruptured wide-necked intracranial aneurysms: A multicenter retrospective study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  13. The use of FD-HPC in Ruptured and Unruptured Aneurysms, the Italian Dataset (RUAID): Preliminary results on feasibility and safety.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  14. Article
  15. Multicenter study of HPC coated p48 and p64 flow diverters for treatment of intracranial aneurysms under dual antiplatelet therapy.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  16. pCONUS 2 and pCONUS 2-HPC in the treatment of wide-necked intracranial aneurysms: Multicentre UK experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Tim Lenz-Habijanphenox GmbH, Lise-Meitner-Allee 31, 44801, Bochum, Germany. Tim.Lenz-Habijan@phenox.info.
P BhogalNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.ORCID http://orcid.org/0000-0002-5514-5237
Marcus PetersAbteilung für Experimentelle Pneumologie, Medizinische Fakultät der Ruhr-Universität Bochum, Bochum, Germany.
Albrecht BufeAbteilung für Experimentelle Pneumologie, Medizinische Fakultät der Ruhr-Universität Bochum, Bochum, Germany.
Rosa Martinez MorenoComplejo Hospitalario Universitario Granada, Granada, Spain.
Catrin Bannewitzphenox GmbH, Lise-Meitner-Allee 31, 44801, Bochum, Germany.
Hermann Monstadtphenox GmbH, Lise-Meitner-Allee 31, 44801, Bochum, Germany.
Hans HenkesNeuroradiologische Klinik, Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
Phenox (Germany) · DEKlinikum Stuttgart · DERuhr University Bochum · DEComplejo Hospitalario Universitario de Granada · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEndovascular stents and flow diverter stents (FDS) have revolutionized the treatment of intradural aneurysms; however, the need for dual anti-platelet treatment (DAPT) limits their use and can cause additional issues. Therefore, there is a need to develop stent coatings that negate the need for DAPT.

methodsTwo different hydrophilic polymer coatings (HPC-I and HPC-II) were used to coat small nickel titanium plates to initially test the hydrophilic properties of these coatings when applied to nickel titanium. The plates were subsequently incubated with non-medicated whole blood from healthy volunteers for 10 min and stained with a CD61 immunofluorescent antibody that allows detection of adherent platelets. The coatings were applied to FDS wires and were again incubated with non-medicated whole blood from the same volunteers. Scanning electron microscopy was used to detect adherent platelets on the wire surface.

resultsThe HPC-II coating (1.12 ± 0.4%) showed a significantly lower CD61 +ve cell count (p ≤ 0.001) compared to both uncoated NiTi plates (48.61 ± 7.3%) and those with the HPC-I coating (mean 40.19 ± 8.9%). Minimal adherent platelets were seen on the FDS nickel titanium wires coated with the HPC-II compared to uncoated FDS under electron microscopy.

conclusionThere is a significant decrease in the number of adherent CD61 +ve platelets on nickel titanium surfaces coated with the HPC-II coating compared to uncoated surfaces. The coating can be successfully applied to the wires of flow diverters. The results of this study are promising with regard to the development of new anti-thrombogenic endovascular devices.

Indexed as

AlloysCoated Materials, BiocompatibleFibrinolytic AgentsHydrophobic and Hydrophilic InteractionsStentsAneurysmDura MaterHumansIn Vitro TechniquesMaterials TestingMicroscopy, ElectronMicroscopy, Electron, ScanningPlatelet AdhesivenessSurface PropertiesAlloysCoated Materials, BiocompatibleFibrinolytic AgentsnitinolAnti-plateletAnti-thrombogenic coatingFlow diverter stent

Identifiers

PMID30039502
PMCPMC6182755
OpenAlexW2884948034

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.