Evidence map›Paper›PMID 30036364›Full record

ArticlePloS one2018

Validation of electronic performance and tracking systems EPTS under field conditions.

Daniel Linke, Daniel Link, Martin Lames

Abstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 85 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
85citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

85 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

25 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Daniel LinkeChair of Performance Analysis and Sports Informatics, Technical University Munich, Munich, Germany.ORCID 0000-0002-5494-917X
Daniel LinkChair of Performance Analysis and Sports Informatics, Technical University Munich, Munich, Germany.ORCID 0000-0003-3606-2986
Martin LamesChair of Performance Analysis and Sports Informatics, Technical University Munich, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to assess the measurement accuracy of the most commonly used tracking technologies in professional team sports (i.e., semi-automatic multiple-camera video technology (VID), radar-based local positioning system (LPS), and global positioning system (GPS)). The position, speed, acceleration and distance measures of each technology were compared against simultaneously recorded measures of a reference system (VICON motion capture system) and quantified by means of the root mean square error RMSE. Fourteen male soccer players (age: 17.4±0.4 years, height: 178.6±4.2 cm, body mass: 70.2±6.2 kg) playing for the U19 Bundesliga team FC Augsburg participated in the study. The test battery comprised a sport-specific course, shuttle runs, and small sided games on an outdoor soccer field. The validity of fundamental spatiotemporal tracking data differed significantly between all tested technologies. In particular, LPS showed higher validity for measuring an athlete's position (23±7 cm) than both VID (56±16 cm) and GPS (96±49 cm). Considering errors of instantaneous speed measures, GPS (0.28±0.07 m⋅s-1) and LPS (0.25±0.06 m⋅s-1) achieved significantly lower error values than VID (0.41±0.08 m⋅s-1). Equivalent accuracy differences were found for instant acceleration values (GPS: 0.67±0.21 m⋅s-2, LPS: 0.68±0.14 m⋅s-2, VID: 0.91±0.19 m⋅s-2). During small-sided games, lowest deviations from reference measures have been found in the total distance category, with errors ranging from 2.2% (GPS) to 2.7% (VID) and 4.0% (LPS). All technologies had in common that the magnitude of the error increased as the speed of the tracking object increased. Especially in performance indicators that might have a high impact on practical decisions, such as distance covered with high speed, we found >40% deviations from the reference system for each of the technologies. Overall, our results revealed significant between-system differences in the validity of tracking data, implying that any comparison of results using different tracking technologies should be done with caution.

Indexed as

ElectronicsGeographic Information SystemsTape RecordingAdolescentAthletic PerformanceHumansMaleReproducibility of ResultsSoccerSports

Identifiers

PMID30036364
PMCPMC6056042

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.