ArticleJournal of thoracic disease2018
Left ventricular assist device exchange for the treatment of HeartMate II pump thrombosis.
Article in Journal of thoracic disease, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 24 citations in OpenAlex.
- Left ventricular assist device exchanges: A safe and effective strategy in the era of limited organ availability.The International journal of artificial organs · 2025Article
- Nine Years of Continuous Flow LVAD (HeartMate 3): Survival and LVAD-Related Complications before and after Hospital Discharge.Journal of cardiovascular development and disease · 2024Article
- Six-month outcomes in postapproval HeartMate3 patients: A single-center US experience.Journal of cardiac surgery · 2022Observational
- Interventional Microbubble Enhanced Sonothrombolysis on Left Ventricular Assist Devices.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022Article
- Continuous-flow left ventricular assist device: Current knowledge, complications, and future directions.Cardiology journal · 2022Review
- Shear-Mediated Platelet Activation is Accompanied by Unique Alterations in Platelet Release of Lipids.Cellular and molecular bioengineering · 2021Article
- Early outcomes with durable left ventricular assist device replacement using the HeartMate 3.The Journal of thoracic and cardiovascular surgery · 2020Article
- The evolution of mechanical circulatory support (MCS): a new wave of developments in MCS and heart failure treatment.Journal of thoracic disease · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPump thrombosis is the most severe and acute complication of left ventricular assist device (LVAD) therapy and treatment remains challenging. Whilst lysis therapy is often not successful, the exchange of the occluded LVAD is currently the most applied therapeutic treatment for this event. With this study we examine the effects of minimal-invasive LVAD exchange on the rate re-thrombosis and outcomes as well as adverse events in the study group.
methodsBetween February 2004 and December 2015 more than 600 LVADs were implanted at our institution. We retrospectively studied a patient cohort of 41 patients who underwent LVAD exchange because of pump thrombosis at a single institution. Outcomes, rates of re-thrombosis and adverse events were analyzed.
resultsBetween February 2004 and December 2015, 87 exchanges of LVADs were performed at a single center. In 41 cases pump thrombosis was the reason for LVAD exchange. A total of 28 patient years (10,276 days) were analyzed. Average ICU stay was 15.8±20.4 days and average in-hospital stay 38.1±37.3 days after LVAD exchange. After thirty days the survival rate was 80.5%, 75.6% after 6 months and 70.7% one year after LVAD exchange. Out of the study cohort, three patients have successfully undergone heart transplantation. Twelve patients suffered a stroke postoperatively (29%). Twelve patients needed postoperative dialysis (29%). No technical complications of the VAD were recorded in the study group. Two patients underwent successful LVAD explantation due to myocardial recovery. One year after LVAD exchange, 14 patients underwent re-exchange due to pump thrombosis (34%). Eight patients suffered from a LVAD related infection out of which two patients were treated by pump exchange. A total of 12 patients died during the complete one year follow up of this study (29%). Four patients died in the second, two in the third and one in the fourth year after LVAD exchange. The remaining 17 patients are still ongoing on the device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.