Evidence map›Paper›PMID 30034015›Full record

ArticleApplied physics letters2018

Deep imaging in highly scattering media by combining reflection matrix measurement with Bessel-like beam based optical coherence tomography.

Qiang Yang, Yusi Miao, Tiancheng Huo, Yan Li, Emon Heidari, Jiang Zhu, Zhongping Chen

Open access · bronzeAbstract read
In one paragraph

Article in Applied physics letters, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Qiang YangBeckman Laser Institute, University of California, Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA.
Yusi Miao
Tiancheng HuoBeckman Laser Institute, University of California, Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA.
Yan Li
Emon Heidari
Jiang ZhuBeckman Laser Institute, University of California, Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA.ORCID 0000-0002-2601-4967
Zhongping Chen
University of California, Irvine · US

Funding

Virtual Photonocs TechnologiesP41EB015890 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI DURKIN, ANTHONY · 2012 to 2017
$7.0M
Phase resolved ARF optical coherence elastography for intravascular imagingR01HL125084 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING, ZHOU, QIFA · 2014 to 2023
$5.6M
Combined OCT/US/PAT system for intravascular ImagingR01HL127271 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING, PATEL, PRANAV · 2015 to 2018
$2.7M
High-resolution Elastographic Assessment of the Optic Nerve HeadR01EY028662 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI CHEN, ZHONGPING, SIGAL, IAN A · 2018 to 2021
$2.7M
High Resolution Elastograpy of Retina Under Prosthetic Electrical StimulationR01EY026091 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI CHEN, ZHONGPING, ZHOU, QIFA · 2016 to 2019
$2.0M
NEI NIH HHS R01 EY026091NEI NIH HHS R01 EY028662NHLBI NIH HHS R01 HL125084NHLBI NIH HHS R01 HL127271NIBIB NIH HHS P41 EB015890
6 · The paper itself

Abstract

Multiple scattering in biomedical tissue limits the imaging depth within a range of 1-2 mm for conventional optical imaging techniques. To extend the imaging depth into the scattering medium, a computational method based on the reflection matrix measurement has been developed to retrieve the singly back-scattered signal light from the dominant detrimental multiple-scattered background. After applying singular value decomposition on the measured matrix in the post-process, the target image underneath the turbid media is clearly recovered. To increase the depth of focus of the incident light by elongating the focal spot along the optical axis, a digital grating pattern is specially designed and displayed on a phase-only spatial light modulator to generate the Bessel-like beam for lateral point scanning. According to the results, the depth of focus is increased up to 2.4 mm which is much longer than the value of ∼50

Identifiers

PMID30034015
PMCPMC6029932
OpenAlexW2809895096

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.