Evidence map›Paper›PMID 30030865›Full record

ArticleJournal of clinical laboratory analysis2019

Antinuclear antibodies detection: A comparative study between automated recognition and conventional visual interpretation.

ZhiYan Li, RuiLin Han, ZhenLin Yan, LiJuan Li, ZhenRu Feng

Abstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

ZhiYan LiDepartment of Clinical Laboratory, Peking University First Hospital, Beijing, China.ORCID http://orcid.org/0000-0003-2866-5832
RuiLin HanDepartment of Clinical Laboratory, Peking University First Hospital, Beijing, China.
ZhenLin YanDepartment of Clinical Laboratory, Peking University First Hospital, Beijing, China.
LiJuan LiDepartment of Clinical Laboratory, Peking University First Hospital, Beijing, China.
ZhenRu FengDepartment of Clinical Laboratory, Peking University First Hospital, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe indirect immunofluorescence assay (IIFA) for the detection of antinuclear antibodies (ANA) was firstly described in 1958 and is still considered the reference method for ANA screening. Currently, an automated processing and recognition system for standardized and efficient ANA interpretation by human epithelial (HEp-2) cell-based immunofluorescence (IIF; EUROPattern Suite, Euroimmun) is available in China.

methodsIn this study, the performance of this novel system for positive/negative classification, pattern recognition (including homogenous, speckled, nucleolar, nuclear dots, cytoplasmic, and centromeres patterns) and titers evaluation was evaluated by comparing to visual interpretation.

resultsReferring to the total of 3681 collected samples, there was an agreement of 98.7% (κ = 0.973) between the visual and automated examination regarding positive/negative discrimination. In sera with single pattern, correct pattern recognition was observed in 94.6% of the samples. The efficiency of automated recognition for single pattern varied for the different patterns. The automatically determined patterns were correct and complete in 1071 of 1620 cases and correct and meaningful but not complete ("main pattern") in another 405 cases, enabling main pattern recognition in 91.1% of all cases. Referring to the titers evaluation, the results within the next titer were considered to be consistent. In 1603 positive sera both by visual and automated evaluation, titers of 1514 sample were consistent, accounting for 94.4%.

conclusionAttributed to the performance characteristics, EUROPattern system is suitable for clinical use as its high degree of automation and result reliability, and may help clinical laboratories to standardize of IIF evaluation.

Indexed as

Antibodies, AntinuclearAutomation, LaboratoryCell LineFluorescent Antibody TechniqueHumansPattern Recognition, AutomatedPattern Recognition, VisualReproducibility of ResultsAntibodies, Antinuclearantinuclear antibodiesautomated interpretationimmunofluorescence patternindirect immunofluorescencevisual interpretation

Identifiers

PMID30030865
PMCPMC6430365

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked