Evidence map›Paper›PMID 30029670›Full record

ArticleJournal of orthopaedic surgery and research2018

Optimization of parameters for femoral component implantation during TKA using finite element analysis and orthogonal array testing.

Zhifang Mou, Wanpeng Dong, Zhen Zhang, Aohan Wang, Guanghong Hu, Bing Wang, Yuefu Dong

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. [Finite element analysis of tibial and femoral resection configurations on varus alignment in total knee arthroplasty].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Zhifang MouDepartment of Critical Care Medicine, The Affiliated Lianyungang Hospital of Xuzhou Medical University/the First People's Hospital of Lianyungang, Lianyungang, China.
Wanpeng DongSchool of Materials Engineering, Shanghai University of Engineering Science, Shanghai, China.
Zhen ZhangSchool of Materials Engineering, Shanghai University of Engineering Science, Shanghai, China.
Aohan WangSchool of Materials Engineering, Shanghai University of Engineering Science, Shanghai, China.
Guanghong HuInstitute of Plasticity Forming Technology & Equipment, Shanghai Jiao Tong University, Shanghai, China.
Bing WangDepartment of Orthopedics, The Affiliated Lianyungang Hospital of Xuzhou Medical University/the First People's Hospital of Lianyungang, Lianyungang, China.
Yuefu DongDepartment of Orthopedics, The Affiliated Lianyungang Hospital of Xuzhou Medical University/the First People's Hospital of Lianyungang, Lianyungang, China. dongyuefu@163.com.
Shanghai University of Engineering Science · CNXuzhou Medical College · CNShanghai Jiao Tong University · CNThe First People’s Hospital of Lianyungang · CN

Funding

National Natural Science Foundation of China (CN) 31670956
6 · The paper itself

Abstract

backgroundIndividualized and accurate implantation of a femoral component during total knee arthroplasty (TKA) is essential in achieving equal distribution of intra-articular stress and long-term survival of the prosthesis. However, individualized component implantation remains challenging. This study aimed to optimize and individualize the positioning parameters of a femoral component in order to facilitate its accurate implantation.

methodsUsing computer-simulated TKA, the positioning parameters of a femoral component were optimized individually by finite element analysis in combination with orthogonal array testing. Flexion angle, valgus angle, and external rotation angle were optimized in order to reduce the peak value of the pressure on the polyethylene liner of the prosthesis.

resultsThe optimal implantation parameters of the femoral component were as follows: 1° flexion, 5° valgus angle, and 4° external rotation. Under these conditions, the peak value of the pressure on the polyethylene liner surface was minimized to 16.46 MPa. Among the three parameters, the external rotation angle had the greatest effect on the pressure, followed by the valgus angle and the flexion angle.

conclusionFinite element analysis in combination with orthogonal array testing can optimize the implantation parameters of a femoral component for TKA. This approach would possibly reduce the wear of the polyethylene liner and prolong the survival of the TKA prosthesis, due to its capacity to minimize stress. This technique represents a new method for preoperative optimization of the implantation parameters that can achieve the best possible TKA outcome.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisFemurFinite Element AnalysisHumansKnee JointPolyethyleneRange of Motion, ArticularRotationPolyethyleneFinite element analysisImplantation parameterOptimizationOrthogonal array testingProsthesisTotal knee arthroplasty (TKA)

Identifiers

PMID30029670
PMCPMC6053797
OpenAlexW2884974220

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.