Evidence map›Paper›PMID 30027749›Full record

ArticleJournal of diabetes science and technology2019

Perceived Usefulness of Continuous Glucose Monitoring Devices at the Workplace: Secondary Analysis of Data From a Qualitative Study.

Jessica Scharf, Xuan Quynh Nguyen, Patricia Vu-Eickmann, Michael Krichbaum, Adrian Loerbroks

Abstract read
In one paragraph

Article in Journal of diabetes science and technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jessica Scharf1 Institute of Occupational, Social and Environmental Medicine, University of Düsseldorf, Düsseldorf, Germany.
Xuan Quynh Nguyen1 Institute of Occupational, Social and Environmental Medicine, University of Düsseldorf, Düsseldorf, Germany.
Patricia Vu-Eickmann1 Institute of Occupational, Social and Environmental Medicine, University of Düsseldorf, Düsseldorf, Germany.
Michael Krichbaum2 Research Institute Diabetes Academy Mergentheim (FIDAM), Bad Mergentheim, Germany.ORCID 0000-0002-5937-1266
Adrian Loerbroks1 Institute of Occupational, Social and Environmental Medicine, University of Düsseldorf, Düsseldorf, Germany.ORCID 0000-0003-2795-8684

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPrevious research suggests that psychosocial working conditions may detrimentally affect diabetes self-management behavior at work, including self-monitoring of glucose levels. We aimed to better understand the potential usefulness of continuous glucose monitoring devices at the workplace according to employees with diabetes.

methodsWe carried out secondary analyses of data from a qualitative study, which sought to explore potential barriers to and solutions for effective diabetes self-management at work. Interviews were carried out in face-to-face contact or by telephone and were transcribed and content-analyzed using MaxQDA. The used topic guide did not specifically inquire after continuous glucose monitoring devices, but views on the suitability of those devices at the workplace repeatedly emerged from the interviews. Data from 25 employed adults with diabetes mellitus type 1 or type 2 on insulin therapy were included.

resultsThe major perceived improvements associated with the use of continuous glucose monitoring devices pertained to their time-saving application that allowed for an increased frequency of glucose level assessments and for socially covert glucose measurement. The socially less noticeable way of monitoring glucose level was specifically perceived as beneficial, as employees with diabetes believed their illness would thereby attract less attention. Fewer or shorter interruptions as well as the reliability of integrated alarm systems were perceived to increase concentration at work and workability.

conclusionsContinuous glucose monitoring devices were perceived to facilitate glucose management at the workplace, which may exert positive effects on compliance as well as functioning at work. Further research would be of interest to statistically confirm our findings in occupational samples.

Indexed as

Health Knowledge, Attitudes, PracticeOccupational HealthSelf CareWorkplaceAdultBiomarkersBlood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1Diabetes Mellitus, Type 2FemaleHumansHypoglycemic AgentsInsulinInterviews as TopicMaleBiomarkersBlood GlucoseHypoglycemic AgentsInsulincontinuous glucose monitoringdiabetes mellitusqualitative studyworkplace

Identifiers

PMID30027749
PMCPMC6399790

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.