ArticleMikrochimica acta2018
Highly sensitive fluorometric determination of thrombin by on-chip signal amplification initiated by terminal deoxynucleotidyl transferase.
Article in Mikrochimica acta, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 12 citations in OpenAlex.
- Aggregation-induced fluorescence of the luminol-terbium(III) complex in polymer nanoparticles for sensitive determination of thrombin.Mikrochimica acta · 2019Article
- CdS quantum dots generated in-situ for fluorometric determination of thrombin activity.Mikrochimica acta · 2019Article
- Fluorometric determination of the activity of the biomarker terminal deoxynucleotidyl transferase via the enhancement of the fluorescence of silver nanoclusters by in-situ grown DNA tails.Mikrochimica acta · 2019Article
- Colorimetric and electrochemical (dual) thrombin assay based on the use of a platinum nanoparticle modified metal-organic framework (type Fe-MIL-88) acting as a peroxidase mimic.Mikrochimica acta · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
Abstract
The article describes an on-chip amplification scheme initiated by a terminal deoxynucleotidyl transferase (TdT) for highly sensitive fluorometric determination of protein. Two thrombin-binding aptamers were designed to capture thrombin as they can form a sandwich structure for improved specificity. An amino-modified aptamer (TBA29) was first immobilized on a silicon chip. After capture of thrombin, a second aptamer (TBA15) was conjugated to the second binding site of thrombin. The 3'-terminal of aptamer TBA15 is exposed on the chip surface, and then fluorescein-labeled 12-dATP associates to the 3'-terminal with the help of TdT. This results in signal amplification, and eventually leads to highly sensitive detection. Under optimal conditions, fluorescence intensity is linearly related to the logarithm of thrombin concentration in the range of 100 fM - 0.1 μM, and the detection limit is as low as 2.0 fM. The assay is sensitive and selective even over potentially interfering proteins and in the presence of human serum. Graphical abstract Schematic strategy for thrombin detection. Two thrombin-binding aptamers were designed to capture thrombin to form a sandwich structure for improved specificity. The protein detection is based on TdT initiated on-chip fluorescent amplification.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.