Evidence map›Paper›PMID 30024907›Full record

ArticlePloS one2018

Red blood cell aggregates and their effect on non-Newtonian blood viscosity at low hematocrit in a two-fluid low shear rate microfluidic system.

Rym Mehri, Catherine Mavriplis, Marianne Fenech

Abstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.

0numbers the graph read from it
0cells of the map it votes in
38citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

38 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Separation of intrinsically magnetic cells using magnetic filters.Separation and purification technology · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Rym MehriDepartment of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada.ORCID 0000-0002-1877-8529
Catherine MavriplisDepartment of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada.
Marianne FenechDepartment of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Red blood cells (RBCs) are the most abundant cells in human blood. Remarkably RBCs deform and bridge together to form aggregates under very low shear rates. The theory and mechanics behind aggregation are, however, not yet completely understood. The main objective of this work is to quantify and characterize RBC aggregates in order to enhance the current understanding of the non-Newtonian behaviour of blood in microcirculation. Suspensions of human blood were flowed and observed in vitro in poly-di-methyl-siloxane (PDMS) microchannels to characterize RBC aggregates. These microchannels were fabricated using standard photolithography methods. Experiments were performed using a micro particle image velocimetry (μPIV) system for shear rate measurements, coupled with a high-speed camera for flow visualization. RBC aggregate sizes were quantified in controlled and measurable shear rate environments for 5, 10 and 15% hematocrit. Aggregate sizes were determined using image processing techniques, while apparent viscosity was measured using optical viscometry. For the samples suspended at 5% H, aggregate size was not strongly correlated with shear rate. For the 10% H suspensions, in contrast, lowering the shear rate below 10 s-1 resulted in a significant increase of RBC aggregate sizes. The viscosity was found to increase with decreasing shear rate and increasing hematocrit, exemplifying the established non-Newtonian shear-thinning behaviour of blood. Increase in aggregation size did not translate into a linear increase of the blood viscosity. Temperature was shown to affect blood viscosity as expected, however, no correlation for aggregate size with temperature was observed. Non-Newtonian parameters associated with power law and Carreau models were determined by fitting the experimental data and can be used towards the simple modeling of blood's non-Newtonian behaviour in microcirculation. This work establishes a relationship between RBC aggregate sizes and corresponding shear rates and one between RBC aggregate sizes and apparent blood viscosity at body and room temperatures, in a microfluidic environment for low hematocrit. Effects of hematocrit, shear rate, viscosity and temperature on RBC aggregate sizes have been quantified.

Indexed as

Blood ViscosityErythrocyte AggregationHematocritErythrocytesHumansMicrocirculationMicrofluidics

Identifiers

PMID30024907
PMCPMC6053157

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.