SynthesisMedicine2018
The diagnostic accuracy of a real-time optoelectronic device in cervical cancer screening: A PRISMA-compliant systematic review and meta-analysis.
Synthesis in Medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Article
- Application value of TPAS staining technique for cervical exfoliated cells in cervical cancer screening.Diagnostic pathology · 2025Article
- Cervical cancer screening: a comparative study of TruScreen vs. Pap Smear.BMC women's health · 2025Observational
- Assessment of the Real-Time Photoelectric Detection Device (TruScreen) in Screening for Cervical Precancerous Lesions in Middle-Aged Women: An Observational Study.Risk management and healthcare policy · 2025Article
- Evaluation of a real-time optoelectronic method for the detection of cervical intraepithelial neoplasia and cervical cancer in patients with different transformation zone types.Scientific reports · 2024Article
- Optimal Screening and Detection Strategies for Cervical Lesions: A Retrospective Study.Journal of Cancer · 2024Article
- Evaluation of a real-time optoelectronic method in the diagnostics of CIN over four years of observations.PloS one · 2021Article
- Comparative Study of Smart Scope® Visual Screening Test with Naked Eye Visual Screening and Pap Test.Asian Pacific journal of cancer prevention : APJCP · 2020Observational
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis study aimed to assess the diagnostic accuracy of a real-time optoelectronic device (TruScreen) for uterine cervical cancer screening.
methodsOn the basis of Preferred Reporting Items for Systematic Reviews and Meta-analyses (the PRISMA statement) we performed this systematic review and meta-analysis. We searched PubMed, EMBASE, the Cochrane Library, CNKI, CBM, and WanFang Data using medical subject headings (MeSH) and text words. Title/abstract screening, full text check, data extraction, and methodological quality assessment (with the QUADAS-2 tool) were performed by 2 reviewers independently. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), the summary receiver operator characteristic curve, and the area under the curve (AUC) were analyzed with Meta-DiSc software. Statistical heterogeneity was evaluated by Cochran's Q test and I, meta-regression was conducted based on patient type, and the possibility of publication bias was evaluated using Deeks funnel plot in Stata software.
resultsOf 293 publications, nine met our inclusion criteria. These studies included a total of 2730 patients and 567 cervical intraepithelial neoplasias. The pooled test characteristics for the TruScreen were as follows: sensitivity 76% (95% CI, 73-80%), specificity 69% (95% CI, 67%-71%), PLR 2.30 (95% CI, 1.59-3.33), and NLR 0.34 (95% CI, 0.23-0.51). The corresponding pooled DOR was 7.03 (95% CI, 3.40-14.55). The AUC was 0.7859 (Q = 0.7236).
conclusionThe diagnostic accuracy of the TruScreen device is moderately good. The study findings are based on Chinese studies only and could not be generalized to other populations.