A novel percutaneous magnetically guided gastrostomy technique without endoscopy or imaging guidance: a feasibility study in a porcine model.

Eduardo Aimore Bonin, Paulo Roberto Walter Ferreira, Marcelo de Paula Loureiro, Thais Andrade Costa-Casagrande, Paolo de Oliveira Salvalaggio, Guilherme Francisco Gomes, Rafael William Noda, Christopher John Gostout, Leandro Totti Cavazzola

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 92% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Eduardo Aimore BoninPostgraduate Program in Surgical Sciences, Faculdade de Medicina da Universidade Federal do Rio Grande do Sul (UFRS), Porto Alegre, RS, Brazil. eabonin@gmail.com.ORCID 0000-0001-8463-2993
Paulo Roberto Walter FerreiraPostgraduate Program in Engineering, Innovation and Entrepreneurship, FADERGS, Porto Alegre, RS, Brazil.
Marcelo de Paula LoureiroMaster Program in Biotechnology, Universidade Positivo, Curitiba, PR, Brazil.
Thais Andrade Costa-CasagrandeVeterinary Sciences Program and Master' in Biotechnology, Universidade Positivo, Curitiba, PR, Brazil.
Paolo de Oliveira SalvalaggioMaster Program in Biotechnology, Universidade Positivo, Curitiba, PR, Brazil.
Guilherme Francisco GomesEndoscopy Unit, Nossa Senhora das Graças Hospital, Curitiba, PR, Brazil.
Rafael William NodaEndoscopy Unit, Nossa Senhora das Graças Hospital, Curitiba, PR, Brazil.
Christopher John GostoutApollo Endosurgery, Inc, Austin, TX, USA.
Leandro Totti CavazzolaPostgraduate Program in Surgical Sciences, Faculdade de Medicina da Universidade Federal do Rio Grande do Sul (UFRS), Porto Alegre, RS, Brazil.
Universidade Positivo · BRHospital Nossa Senhora das Graças · BRUniversidade Federal do Rio Grande do Sul · BRApollo Endosurgery (United States) · USFaculdade de Desenvolvimento do Rio Grande do Sul · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn order to simplify a percutaneous gastrostomy procedure and avoid the need of endoscopy or imaging methods, a novel percutaneous magnetically guided gastrostomy (PMG) technique was conceived. The aim of the present study is to evaluate the feasibility of a novel PMG technique with no endoscopy or any imaging guidance in a porcine model.

methodsFourteen crossbred domestic pigs were used for prototype development (cadaveric experiments) and proof-of concept, survival study. The magnetic device was conceived using commercially available rare-earth neodymium-based magnets. The experimental design consisted of developing an internal magnetic gastric tube prototype to be orally inserted and coupled to an external magnet placed on the skin, which facilitated stomach and abdominal wall apposition for blind percutaneous gastrostomy tube placement. Then, a gastrostomy tube was percutaneously and blindly placed.

resultsTwelve procedures were undertaken in animal cadavers and two in live models. The technique chosen consisted of using a magnetic gastric tube prototype using six 1 × 1-cm-ring magnets attached to its end. This device enabled successful magnetic coupling with a large (5 cm in diameter) magnet disc placed on the skin. For gastric tube placement, a direct trocar insertion allowed easier and safer placement of a gastric tube as compared to a needle-guide-wire dilation (Seldinger-based) technique. Gastropexy was added to avoid early gastric tube displacement. This novel PMG technique was feasible in a live model experiment.

conclusionsA novel magnetically guided percutaneous gastrostomy tube insertion technique without the use of endoscopy or image-guidance was successful in a porcine model. A non-inferiority experimental controlled study comparing this technique to percutaneous endoscopic gastrostomy is needed to confirm its efficacy and safety.

Indexed as

GastrostomyIntubation, GastrointestinalMagnetsAnimalsFeasibility StudiesGastropexyIntraoperative CareIntraoperative ComplicationsModels, AnatomicStomachSwineMagnetPercutaneous endoscopic gastrostomySurgical deviceSurgical technique

Identifiers

PMID30022288
OpenAlexW2883072296

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.