Evidence map›Paper›PMID 30012951›Full record

ArticleSensors (Basel, Switzerland)2018

Potentiometric Sensors for Iodide and Bromide Based on Pt(II)-Porphyrin.

Dana Vlascici, Nicoleta Plesu, Gheorghe Fagadar-Cosma, Anca Lascu, Mihaela Petric, Manuela Crisan, Anca Belean, Eugenia Fagadar-Cosma

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. The Influence of the Nature of the Polymer Incorporating the Same AInternational journal of molecular sciences · 2023
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Dana VlasciciFaculty of Chemistry, Biology, Geography, West University of Timisoara, 4 V. Parvan Ave, Timisoara 300223, Romania. danavlascici@yahoo.com.
Nicoleta PlesuInstitute of Chemistry Timişoara of Romanian Academy, 24 M. Viteazul Ave, Timisoara 300223, Romania. plesu_nicole@yahoo.com.
Gheorghe Fagadar-CosmaFaculty of Industrial Chemistry and Environmental Engineering, Politehnica University Timisoara, Pta Victoriei 2, Timisoara 300006, Romania. gfagadar@yahoo.com.
Anca LascuInstitute of Chemistry Timişoara of Romanian Academy, 24 M. Viteazul Ave, Timisoara 300223, Romania. ancalascu@yahoo.com.
Mihaela PetricInstitute of Chemistry Timişoara of Romanian Academy, 24 M. Viteazul Ave, Timisoara 300223, Romania. mihaelapetric@yahoo.com.
Manuela CrisanInstitute of Chemistry Timişoara of Romanian Academy, 24 M. Viteazul Ave, Timisoara 300223, Romania. mdorosencu@yahoo.com.
Anca BeleanInstitute of Chemistry Timişoara of Romanian Academy, 24 M. Viteazul Ave, Timisoara 300223, Romania. anca_palade@yahoo.com.
Eugenia Fagadar-CosmaInstitute of Chemistry Timişoara of Romanian Academy, 24 M. Viteazul Ave, Timisoara 300223, Romania. efagadar@yahoo.com.ORCID 0000-0001-5668-709X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pt(II) 5,10,15,20-tetra(4-methoxy-phenyl)-porphyrin (PtTMeOPP) was used in the construction of new ion-selective sensors. The potentiometric response characteristics (slope and selectivity) of iodide and bromide-selective electrodes based on (PtTMeOPP) metalloporphyrin in

Indexed as

bromideiodideion-selective electrodepotentiometryPt-metalloporphyrinPVC membrane

Identifiers

PMID30012951
PMCPMC6068665

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.