ArticleRadiation oncology (London, England)2018
Real-time intra-fraction motion management in breast cancer radiotherapy: analysis of 2028 treatment sessions.
Article in Radiation oncology (London, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
34 citing papers in PubMed.
- The Prospective SPOTLESS Trial: Setup Accuracy of Tattoo-Less Surface-Guided Breast Radiotherapy Including Regional Nodal Irradiation.Journal of clinical medicine · 2026Article
- To shift or not to shift: identifying and correcting patient motion after couch rotations in non-coplanar intracranial radiosurgery with stereoscopic X-ray imaging.Journal of applied clinical medical physics · 2026Article
- Beyond the snapshot: continuous optical surface monitoring reveals non-linear temporal dynamics and postural stability window in free-breathing breast radiotherapy.Frontiers in oncology · 2026Article
- Postmastectomy Radiation Therapy: An ASTRO/ASCO/SSO Clinical Practice Guideline.Annals of surgical oncology · 2025Article
- Validation of in vivo dose using EPID combined with fan-beam CT guidance in post-breast-conserving radiotherapy for early-stage breast cancer.BMC cancer · 2025Article
- Reproducibility and stability of voluntary deep inspiration breath hold and free breath in breast radiotherapy based on real-time 3-dimensional optical surface imaging system.Radiation oncology (London, England) · 2024Article
- Setup margins based on the inter- and intrafractional setup error of left-sided breast cancer radiotherapy using deep inspiration breath-hold technique (DIBH) and surface guided radiotherapy (SGRT).Journal of applied clinical medical physics · 2024Article
- Robustness analysis of surface-guided DIBH left breast radiotherapy: personalized dosimetric effect of real intrafractional motion within the beam gating thresholds.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2024Article
- Setup accuracy and margins for surface-guided radiotherapy (SGRT) of head, thorax, abdomen, and pelvic target volumes.Scientific reports · 2023Article
- Development of a dynamic motion platform with two independent drive systems for radiotherapy.Journal of applied clinical medical physics · 2023Article
- A dose planning study for cardiac and lung dose sparing techniques in left breast cancer radiotherapy: Can free breathing helical tomotherapy be considered as an alternative for deep inspiration breath hold?Technical innovations & patient support in radiation oncology · 2023Article
- Prerequisites for the clinical implementation of a markerless SGRT-only workflow for the treatment of breast cancer patients.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2023Article
- Application of tangent-arc technology for deep inspiration breath-hold radiotherapy in left-sided breast cancer.Frontiers in oncology · 2023Article
- The factors of fiducial marker motions and individual margin assessment in postoperative breast cancer radiotherapy.Annals of translational medicine · 2022Article
- ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X-ray positioning.Journal of applied clinical medical physics · 2022Article
- Intrafraction motion during radiotherapy of breast tumor, breast tumor bed, and individual axillary lymph nodes on cine magnetic resonance imaging.Physics and imaging in radiation oncology · 2022Article
- Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2022Article
- Target motion management in breast cancer radiation therapy.Radiology and oncology · 2021Review
- Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe.Scientific reports · 2021Article
- Intra-fraction motion monitoring during fast modulated radiotherapy delivery in a closed-bore gantry linac.Physics and imaging in radiation oncology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIntra-fraction motion represents a crucial issue in the era of precise radiotherapy in several settings, including breast irradiation. To date, only few data exist on real-time measured intra-fraction motion in breast cancer patients. Continuous surface imaging using visible light offers the capability to monitor patient movements in three-dimensional space without any additional radiation exposure. The aim of the present study was to quantify the uncertainties of possible intra-fractional motion during breast radiotherapy. MATERIAL AND
methodsOne hundred and four consecutive patients that underwent postoperative radiotherapy following breast conserving surgery or mastectomy were prospectively evaluated during 2028 treatment sessions. During each treatment session the patients' motion was continuously measured using the Catalyst™ optical surface scanner (C-RAD AB, Sweden) and compared to a reference scan acquired at the beginning of each session. The Catalyst system works through an optical surface imaging with light emitting diode (LED) light and reprojection captured by a charge coupled device (CCD) camera, which provide target position control during treatment delivery with a motion detection accuracy of 0.5 mm. For 3D surface reconstruction, the system uses a non-rigid body algorithm to calculate the distance between the surface and the isocentre and using the principle of optical triangulation. Three-dimensional deviations and relative position differences during the whole treatment fraction were calculated by the system and analyzed statistically.
resultsOverall, the maximum magnitude of the deviation vector showed a mean change of 1.93 mm ± 1.14 mm (standard deviation [SD]) (95%-confidence interval: [0.48-4.65] mm) and a median change of 1.63 mm during dose application (beam-on time only). Along the lateral and longitudinal axis changes were quite similar (0.18 mm ± 1.06 mm vs. 0.17 mm ± 1.32 mm), on the vertical axis the mean change was 0.68 mm ± 1.53 mm. The mean treatment session time was 154 ± 53 (SD) seconds and the mean beam-on time only was 55 ± 16 s. According to Friedman's test differences in the distributions of the three possible directions (lateral, longitudinal and vertical) were significant (p < 0.01), in post-hoc analysis there were no similarities between any two of the three directions.
conclusionThe optical surface imaging system is an accurate and easy tool for real-time motion management in breast cancer radiotherapy. Intra-fraction motion was reported within five millimeters in all directions. Thus, intra-fraction motion in our series of 2028 treatment sessions seems to be of minor clinical relevance in postoperative radiotherapy of breast cancer.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.