Evidence map›Paper›PMID 30008517›Full record

ArticleJournal of alloys and compounds2018

Mn Doped AZIS/ZnS Nanocrystals (NCs): Effects of Ag and Mn Levels on NC Optical Properties.

Masoumeh Saber Zaeimian, Brandon Gallian, Clay Harrison, Yu Wang, Jialong Zhao, Xiaoshan Zhu

Abstract read
In one paragraph

Article in Journal of alloys and compounds, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Development of Time-Resolved Luminescence Measurement Instruments for Biosensing and Bioimaging - An Overview.Measurement : journal of the International Measurement Confederation · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Masoumeh Saber ZaeimianDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV, USA.
Brandon GallianDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV, USA.
Clay HarrisonDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV, USA.
Yu WangKey Laboratory of Functional Materials Physics and Chemistry of The Ministry of Education, Jilin Normal University, Jilin, China.
Jialong ZhaoKey Laboratory of Functional Materials Physics and Chemistry of The Ministry of Education, Jilin Normal University, Jilin, China.
Xiaoshan ZhuDepartment of Electrical and Biomedical Engineering, University of Nevada Reno, NV, USA.

Funding

Virtual Reality and Augmented Reality CoreP20GM103650 · NIGMS · UNIVERSITY OF NEVADA RENO · PI WEBSTER, MICHAEL A · 2012 to 2022
$20.9M
Time-Gated Fluorescence Lateral Flow Immunoassay for Melioidosis DiagnosisR15GM135855 · NIGMS · UNIVERSITY OF NEVADA RENO · PI ZHU, XIAOSHAN · 2020 to 2020
$426k
NIGMS NIH HHS P20 GM103650NIGMS NIH HHS R15 GM135855
6 · The paper itself

Abstract

In this work, Mn-doped AZIS/ZnS NCs were prepared using a nucleation doping approach with the tuning of Mn and Ag levels in their synthesis. The optical properties of Mn:AZIS/ZnS NCs are found to be significantly affected by Ag and Mn levels. Specifically, more Ag and Mn atoms in Mn:AZIS/ZnS NCs cause their fluorescence red-shift, and as the Ag or Mn level reaches a high threshold, the fluorescence lifetime of Mn:AZIS/ZnS NC has a significant drop. The reasons for the effects of Mn and Ag levels on NC optical properties were explored and discussed. Through this study, it is also found that with certain Ag and Mn levels in synthesis, some Mn:AZIS/ZnS NCs present optimal optical properties including high brightness (QY > 40%), long fluorescence lifetime (> 1.2 ms), low energy for excitation (excitable at 405 nm), and no reabsorption. The feasibility of the optimized NCs for time-gated fluorescence measurement using a portable/compact instrument was further demonstrated, which indicates the application potential of the NCs in time-gated biosensing including point-of-care testing. Notably, this study also discloses that Mn:AZIS/ZnS NCs with different lifetimes can be achieved by tuning Mn and Ag levels in synthesis, which may further broaden the applications of Mn:AZIS/ZnS NCs in multiplexing detection/measurement.

Identifiers

PMID30008517
PMCPMC6039121

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.