Comparison of two commercial quality control sera for adrenocorticotropin (ACTH) used in Elecsys

Zhi-Qi Wu, Hua-Guo Xu

Abstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Zhi-Qi WuDepartment of Laboratory Medicine, the First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
Hua-Guo XuDepartment of Laboratory Medicine, the First Affiliated Hospital of Nanjing Medical University, Nanjing, China.ORCID http://orcid.org/0000-0001-7170-9445

Funding

Key laboratory for Laboratory Medicine of Jiangsu Province ZDXKB2016005National Key Clinical Department of Laboratory Medicine of China in NanjingNational Natural Science Foundation of China 81302531Natural Science Foundation of Jiangsu Province of China BK20131018Priority Academic Program Development of Jiangsu Higher Education InstitutionsTalents Planning of Six Summit Fields of Jiangsu Province 2013-WSN-037
6 · The paper itself

Abstract

objectivesThe purpose of our study was to investigate whether the storage time and temperature of internal quality control (IQC) material influence the result of ACTH in IQC measurements. DESIGN AND

methodsFive levels of IQC materials from two manufacturers were tested through the precision of ACTH, the three freeze/thaw cycles, and the storage time and temperature to evaluate the stability of IQC material. All commercial control materials were simultaneously tested three times a day for five consecutive days.

resultsTotal precision of three levels of Bio-Rad IQC sera was 13.93%, 16.45%, and 15.98%, respectively, but repeatability was <2%. The concentration of ACTH decreased by 30%-50% after 3 freeze/thaw cycles. At room temperature, the concentration of ACTH from 3 levels decreased by 16.60%, 17.98%, and 17.20%, respectively, after 0.5 hours, and 70.54%, 74.36%, and 72.03%, respectively, after 4 hours. However, after 2 hours of storage at 4°C, the decline in the measured ACTH IQC was 8.04%, 11.84%, and 10.11%, respectively. Total precision of Roche IQC was 1.17% and 1.08%, respectively. After 3 freeze/thaw cycles, the concentration of ACTH decreased <5%. After 4 hours, the change of ACTH still steadied within 5% both at the room temperature and at 4°C.

conclusionRoche is a better choice for ACTH of IQC material in Elecsys

Indexed as

Adrenocorticotropic HormoneHumansImmunoassayProtein StabilityQuality ControlReference StandardsReproducibility of ResultsTemperatureTime FactorsAdrenocorticotropic Hormoneadrenocorticotropininternal quality control

Identifiers

PMID30006935
PMCPMC6430340

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.