ArticleEye and vision (London, England)2018

Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed.

Yilei Shao, Aizhu Tao, Hong Jiang, Meixiao Shen, Dexi Zhu, Fan Lu, Carol L Karp, Yufeng Ye, Jianhua Wang

Open access · diamondAbstract read
In one paragraph

Article in Eye and vision (London, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Yilei Shao1Bascom Palmer Eye Institute, University of Miami, Miami, FL USA.
Aizhu Tao1Bascom Palmer Eye Institute, University of Miami, Miami, FL USA.
Hong Jiang1Bascom Palmer Eye Institute, University of Miami, Miami, FL USA.
Meixiao Shen2School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang China.
Dexi Zhu2School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang China.
Fan Lu2School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang China.
Carol L Karp1Bascom Palmer Eye Institute, University of Miami, Miami, FL USA.
Yufeng Ye1Bascom Palmer Eye Institute, University of Miami, Miami, FL USA.
Jianhua Wang1Bascom Palmer Eye Institute, University of Miami, Miami, FL USA.
Wenzhou Medical University · CNUniversity of Miami · US

Funding

Shared Equipment ModuleP30EY014801 · NEI · UNIVERSITY OF MIAMI SCHOOL OF MEDICINE · PI Victor L Perez · 2004 to 2026
$12.2M
Optical coherence tomography equipped wavefront system for studying accommodationR21EY021336 · NEI · NEW ENGLAND COLLEGE OF OPTOMETRY · PI HE, JI CHANG · 2012 to 2013
$395k
NEI NIH HHS P30 EY014801NEI NIH HHS R21 EY021336
6 · The paper itself

Abstract

backgroundSpectral domain optical coherence tomography (SD-OCT) was a useful tool to study accommodation in human eye, but the maximum image depth is limited due to the decreased signal-to-noise ratio (SNR). In this study, improving optical resolutions, speeds and the SNR were achieved by custom built SD-OCT, and the evaluation of the impact of the improvement during accommodation was investigated.

methodsThree systems with different spectrometer designs, including two Charge Coupled Device (CCD) cameras and one Complementary Metal-Oxide-Semiconductor Transistor (CMOS) camera, were tested. We measured the point spread functions of a mirror at different positions to obtain the axial resolution and the SNR of three OCT systems powered with a light source with a 50 nm bandwidth, centered at a wavelength of 840 nm. Two normal subjects, aged 26 and 47, respectively, and one 75-year-old patient with an intraocular lens implanted were imaged.

resultsThe results indicated that spectrometers using cameras with 4096 camera pixels optimized the axial resolutions, due to the use of the full spectrum provided by the light source. The CCD camera system with 4096 pixels had the highest SNR and the best image quality. The system with the CMOS camera with 4096 pixels had the highest speed but had a compromised SNR compared to the CCD camera with 4096 pixels.

conclusionsUsing these three OCT systems, we imaged the anterior segment of the human eye before and after accommodation, which showed similar results among the different systems. The system using the CMOS camera with an ultra-long scan depth, high resolution and high scan speed exhibited the best overall performance and therefore was recommended for imaging real-time accommodation.

Indexed as

AccommodationAnterior segmentAxial resolutionOptical coherence tomographySignal-to-noise ratio

Identifiers

PMID30003116
PMCPMC6036665
OpenAlexW2823889789

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.