Evidence map›Paper›PMID 29994774›Full record

ArticleIEEE transactions on biomedical circuits and systems2018

A Bidirectional-Current CMOS Potentiostat for Fast-Scan Cyclic Voltammetry Detector Arrays.

Carlos I Dorta-Quinones, Meng Huang, John C Ruelas, Joannalyn Delacruz, Alyssa B Apsel, Bradley A Minch, Manfred Lindau

Abstract read
In one paragraph

Article in IEEE transactions on biomedical circuits and systems, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Carlos I Dorta-Quinones
Meng Huang
John C Ruelas
Joannalyn Delacruz
Alyssa B Apsel
Bradley A Minch
Manfred Lindau

Funding

Scalable sensor array platform for analysis of quantal transmitter release eventsR01MH095046 · NIMH · CORNELL UNIVERSITY · PI LINDAU, MANFRED · 2011 to 2014
$1.5M
Scalable amperometric microchip array for high-throughput screening of small molecules, peptides or genetic perturbations for modulation of quantal transmitter releaseR43MH109212 · NIMH · EXOCYTRONICS, LLC · PI LINDAU, MANFRED, LIU, XIN ALICE · 2016 to 2017
$869k
NIMH NIH HHS R01 MH095046NIMH NIH HHS R43 MH109212
6 · The paper itself

Abstract

A potentiostat circuit for the application of bipolar electrode voltages and detection of bidirectional currents using a microelectrode array is presented. The potentiostat operates as a regulated-cascode amplifier for positive input currents, and as an active-input regulated-cascode mirror for negative input currents. This topology enables constant-potential amperometry and fast-scan cyclic voltammetry (FSCV) at microelectrode arrays for parallel recording of quantal release events, electrode impedance characterization, and high-throughput drug screening. A 64-channel FSCV detector array, fabricated in a 0.5-$\mu$m, 5-V CMOS process, is also demonstrated. Each detector occupies an area of 45  $\mu$m $\times$ 30 $\mu$m and consists of only 14 transistors and a 50-fF integrating capacitor. The system was validated using prerecorded input stimuli from actual FSCV measurements at a carbon-fiber microelectrode.

Indexed as

MicroelectrodesAnimalsBiosensing TechniquesCell MembraneElectrochemical TechniquesExocytosisHumansNeuronsNoise

Identifiers

PMID29994774
PMCPMC6131114

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.