Evidence map›Paper›PMID 29989796›Full record

ArticleAnalytical chemistry2018

DIA-SIFT: A Precursor and Product Ion Filter for Accurate Stable Isotope Data-Independent Acquisition Proteomics.

Sarah E Haynes, Jaimeen D Majmudar, Brent R Martin

Abstract read
In one paragraph

Article in Analytical chemistry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sarah E HaynesDepartment of Chemistry , University of Michigan , 930 N. University Avenue, Ann Arbor , Michigan 48109 , United States.
Jaimeen D MajmudarDepartment of Chemistry , University of Michigan , 930 N. University Avenue, Ann Arbor , Michigan 48109 , United States.ORCID 0000-0002-4256-9364
Brent R MartinDepartment of Chemistry , University of Michigan , 930 N. University Avenue, Ann Arbor , Michigan 48109 , United States.ORCID 0000-0002-7136-2397

Funding

MICHIGAN CHEMISTRY-BIOLOGY INTERFACE TRAINING PROGRAMT32GM008597 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI MONTGOMERY, JOHN · 1996 to 2018
$5.0M
Multiscale chemical approaches to map oxidative stressDP2GM114848 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI MARTIN, BRENT RANDALL · 2014 to 2014
$2.2M
NIGMS NIH HHS DP2 GM114848NIGMS NIH HHS T32 GM008597
6 · The paper itself

Abstract

Quantitative mass spectrometry-based protein profiling is widely used to measure protein levels across different treatments or disease states, yet current mass spectrometry acquisition methods present distinct limitations. While data-independent acquisition (DIA) bypasses the stochastic nature of data-dependent acquisition (DDA), fragment spectra derived from DIA are often complex and challenging to deconvolve. In-line ion mobility separation (IMS) adds an additional dimension to increase peak capacity for more efficient product ion assignment. As a similar strategy to sequential window acquisition methods (SWATH), IMS-enabled DIA methods rival DDA methods for protein annotation. Here we evaluate IMS-DIA quantitative accuracy using stable isotope labeling by amino acids in cell culture (SILAC). Since SILAC analysis doubles the sample complexity, we find that IMS-DIA analysis is not sufficiently accurate for sensitive quantitation. However, SILAC precursor pairs share common retention and drift times, and both species cofragment to yield multiple quantifiable isotopic y-ion peak pairs. Since y-ion SILAC ratios are intrinsic for each quantified precursor, combined MS1 and y-ion ratio analysis significantly increases the total number of measurements. With increased sampling, we present DIA-SIFT ( SILAC Intrinsic Filtering Tool), a simple statistical algorithm to identify and eliminate poorly quantified MS1 and/or MS2 events. DIA-SIFT combines both MS1 and y-ion ratios, removes outliers, and provides more accurate and precise quantitation (<15% CV) without removing any proteins from the final analysis. Overall, pooled MS1 and MS2 quantitation increases sampling in IMS-DIA SILAC analyses for accurate and precise quantitation.

Indexed as

Amino AcidsCell Culture TechniquesHEK293 CellsHumansIsotope LabelingMass SpectrometryProteomeProteomicsSoftwareAmino AcidsProteome

Identifiers

PMID29989796
PMCPMC6188651

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.