The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

Ji Young Jeon, Sheen-Woo Lee, Yu Mi Jeong, Han Joo Baek

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Dual-Energy CT Images: Pearls and Pitfalls.Radiographics : a review publication of the Radiological Society of North America, Inc
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ji Young JeonDepartment of Radiology, Gil Medical Center, Gachon University College of Medicine, 21 Namdong-daero, 774beon-gil, Namdong-gu, Incheon, 21565, Republic of Korea. mdjeonjy@gmail.com.ORCID http://orcid.org/0000-0002-9864-4765
Sheen-Woo LeeDepartment of Radiology, Gil Medical Center, Gachon University College of Medicine, 21 Namdong-daero, 774beon-gil, Namdong-gu, Incheon, 21565, Republic of Korea.
Yu Mi JeongDepartment of Radiology, Gil Medical Center, Gachon University College of Medicine, 21 Namdong-daero, 774beon-gil, Namdong-gu, Incheon, 21565, Republic of Korea.
Han Joo BaekDivision of Rheumatology, Department of Internal Medicine, Gil Medical Center, Gachon University College of Medicine, 21 Namdong-daero, 774beon-gil, Namdong-gu, Incheon, 21565, Republic of Korea.

Funding

Gachon University GCU-2017-5259
6 · The paper itself

Abstract

objectivesIn dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared with the conventional 80/140 kV.

methodsSeventy-four patients with suspected gout who underwent dual-source DECT examinations scanned at 80/140 kV (n = 37) and at 80/150 Sn kV (n = 37) were included. Patients' age, sex, and serum uric acid levels were matched between the two groups. The types and incidence of image artefacts and radiation dose were evaluated.

resultsThe 80/150 Sn kV group had significantly fewer patients with artefacts, compared to the 80/140 kV group [11 (30 %) of 37 vs 35 (94.6 %) of 37, p < 0.001]. Except for the motion artefact, the rest of the artefacts-skin, nail bed, submillimetre, motion, vascular, beam-hardening, clumpy artefact along tendon-were significantly less observed in the 80/150 Sn kV acquisitions. The dose-length product (DLP) and effective dose were significantly lower for the 80/150 Sn kV acquisitions compared with the 8s0/140 kV scans (DLP: 104.46 ± 10.66 mGy·cm vs 344.70 ± 56.39 mGy·cm, p < 0.001; effective dose: 1.04 ± 0.11 mSv vs 3.45 ± 0.56 mSv, p < 0.001).

conclusionsThe 80/150 Sn kV voltage combination in dual-source DECT system could be used as one of the artefact reduction methods while reducing radiation dose for gout protocol when compared to the conventional 80/140 kV. KEY POINTS: • DECT has emerged as the leading modality for non-invasive diagnosis of gout. • Various X-ray tube voltage combinations are now feasible in dual-source DECT. • The 80/150 Sn kV acquisition could facilitate artefact reduction in gout protocol.

Indexed as

ArtifactsRadiation DosageAgedFemaleGoutHumansImage EnhancementMaleMiddle AgedRadiography, Dual-Energy Scanned ProjectionRetrospective StudiesTinTomography, X-Ray ComputedTinArtefactsGoutRadiation dosageTinTomography, X-ray computed