Evidence map›Paper›PMID 29984883›Full record

ArticleJournal of applied clinical medical physics2018

Enhancement of megavoltage electronic portal images for markerless tumor tracking.

Kwang-Ho Cheong, Jai-Woong Yoon, Soah Park, Taejin Hwang, Sei-Kwon Kang, Taeryool Koo, Tae Jin Han, Haeyoung Kim, Me Yeon Lee, Kyoung Ju Kim and 1 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kwang-Ho CheongDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Jai-Woong YoonDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Soah ParkDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Taejin HwangDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Sei-Kwon KangDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Taeryool KooDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Tae Jin HanDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Haeyoung KimDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Me Yeon LeeDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Kyoung Ju KimDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.
Hoonsik BaeDepartment of Radiation Oncology, Hallym University College of Medicine, Seoul, Korea.

Funding

Ministry of Science, ICT & Future Planning 2016M2A2A7952291
6 · The paper itself

Abstract

purposeThe poor quality of megavoltage (MV) images from electronic portal imaging device (EPID) hinders visual verification of tumor targeting accuracy particularly during markerless tumor tracking. The aim of this study was to investigate the effect of a few representative image processing treatments on visual verification and detection capability of tumors under auto tracking.

methodsImages of QC-3 quality phantom, a single patient's setup image, and cine images of two-lung cancer patients were acquired. Three image processing methods were individually employed to the same original images. For each deblurring, contrast enhancement, and denoising, a total variation deconvolution, contrast-limited adaptive histogram equalization (CLAHE), and median filter were adopted, respectively. To study the effect of image enhancement on tumor auto-detection, a tumor tracking algorithm was adopted in which the tumor position was determined as the minimum point of the mean of the sum of squared pixel differences (MSSD) between two images. The detectability and accuracy were compared.

resultsDeblurring of a quality phantom image yielded sharper edges, while the contrast-enhanced image was more readable with improved structural differentiation. Meanwhile, the denoising operation resulted in noise reduction, however, at the cost of sharpness. Based on comparison of pixel value profiles, contrast enhancement outperformed others in image perception. During the tracking experiment, only contrast enhancement resulted in tumor detection in all images using our tracking algorithm. Deblurring failed to determine the target position in two frames out of a total of 75 images. For original and denoised set, target location was not determined for the same five images. Meanwhile, deblurred image showed increased detection accuracy compared with the original set. The denoised image resulted in decreased accuracy. In the case of contrast-improved set, the tracking accuracy was nearly maintained as that of the original image.

conclusionsConsidering the effect of each processing on tumor tracking and the visual perception in a limited time, contrast enhancement would be the first consideration to visually verify the tracking accuracy of tumors on MV EPID without sacrificing tumor detectability and detection accuracy.

Indexed as

AlgorithmsHumansImage EnhancementImage Processing, Computer-AssistedNeoplasmsPhantoms, ImagingRadiographycontrast enhancementdeblurringdenoisingimage qualitymegavoltage electronic portal imaging devicetumor tracking

Identifiers

PMID29984883
PMCPMC6123147

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.