ArticleTissue engineering. Part C, Methods2018
Improving Surgical Methods for Studying Vascular Grafts in Animal Models.
Article in Tissue engineering. Part C, Methods, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 17 citations in OpenAlex.
- Leveraging printability and biocompatibility in materials for printing implantable vessel scaffolds.Materials today. Bio · 2024Review
- Platelet Membrane-Encapsulated Poly(lactic-International journal of pharmaceutics: X · 2024Article
- Enhanced hemocompatibility and rapid magnetic anastomosis of electrospun small-diameter artificial vascular grafts.Frontiers in bioengineering and biotechnology · 2024Article
- Biodegradable external wrapping promotes favorable adaptation in an ovine vein graft model.Acta biomaterialia · 2022Article
- Review
- 3D printing of tissue engineering scaffolds: a focus on vascular regeneration.Bio-design and manufacturing · 2021Review
- Blood Flow Within Bioengineered 3D Printed Vascular Constructs Using the Porcine Model.Frontiers in cardiovascular medicine · 2021Article
- Current understanding of intimal hyperplasia and effect of compliance in synthetic small diameter vascular grafts.Biomaterials science · 2020Review
- Fucoidan functionalization on poly(vinyl alcohol) hydrogels for improved endothelialization and hemocompatibility.Biomaterials · 2020Article
- Quantifying Physical Thrombus Characteristics on Cardiovascular Biomaterials Using MicroCT.Methods and protocols · 2020Article
- Bioconjugation of a Collagen-Mimicking Peptide Onto Poly(vinyl alcohol) Encourages Endothelialization While Minimizing Thrombosis.Frontiers in bioengineering and biotechnology · 2020Article
- Biomimetic modification of poly(vinyl alcohol): Encouraging endothelialization and preventing thrombosis with antiplatelet monotherapy.Acta biomaterialia · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
Abstract
While clinical vascular grafting uses an end-to-side surgical method, researchers primarily use end-to-end implant techniques in preclinical models. This may be due in part to the limitations of using small animal models in research. The work presented here provides support and evidence for the improvement of vascular graft implant techniques by demonstrating the successful implantation of experimental grafts into both large and small animal models. Specifically, models of aortoiliac baboon (Papio anubis) bypass and common carotid rabbit (Oryctolagus cuniculus) bypass were used to test vascular grafts for thrombosis and vascular healing after 1 month using an end-to-side anastomosis grafting procedure. Patency was evaluated with ultrasound or histological techniques, and neointimal growth was quantified with histology. In the development of this procedure for small animals, both an end-to-end/end-to-side and an end-to-side/end-to-side configuration were tested in rabbits. One hundred percent of rabbit implants (2/2) with an end-to-end/end-to-side configuration were patent at explant. However, with the end-to-side/end-to-side configuration, 66% (6/9) of rabbit implants and 93% (13/14) of baboon implants remained patent at 1 month, suggesting the importance of replicating the end-to-side method for testing vascular grafts for clinical use. This study describes feasible preclinical surgical procedures, which simulate clinical vascular bypass grafts even in small animals. Widespread implementation of these end-to-side surgical techniques in these or other animals should improve the quality of experimental, preclinical testing and ultimately increase the likelihood of translating new vascular graft technologies into clinical applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.