Evidence map›Paper›PMID 29984616›Full record

ArticleTissue engineering. Part C, Methods2018

Improving Surgical Methods for Studying Vascular Grafts in Animal Models.

Deirdre E J Anderson, Grace Pohan, Jaishankar Raman, Filip Konecny, Evelyn K F Yim, Monica T Hinds

Abstract read
In one paragraph

Article in Tissue engineering. Part C, Methods, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Platelet Membrane-Encapsulated Poly(lactic-International journal of pharmaceutics: X · 2024
    Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Deirdre E J Anderson1 Department of Biomedical Engineering, Oregon Health & Science University , Portland, Oregon.
Grace Pohan2 Department of Chemical Engineering, University of Waterloo , Waterloo, Ontario, Canada .
Jaishankar Raman3 Division of Cardiothoracic Surgery, Oregon Health & Science University , Portland, Oregon.
Filip Konecny4 Division of Plastic Surgery, Department of Surgery, McMaster University , Hamilton, Ontario, Canada .
Evelyn K F Yim2 Department of Chemical Engineering, University of Waterloo , Waterloo, Ontario, Canada .
Monica T Hinds1 Department of Biomedical Engineering, Oregon Health & Science University , Portland, Oregon.
Oregon Health & Science University · USUniversity of Waterloo · CAMcMaster University · CA

Funding

Upgrade of confocal microscopy at the Oregon National Primate Research CenterP51OD011092 · OD · OREGON HEALTH & SCIENCE UNIVERSITY · PI Bonnie J. Nagel · 2012 to 2026
$203.9M
Surface Modification Compliant Vascular GraftsR01HL130274 · NHLBI · OREGON HEALTH & SCIENCE UNIVERSITY · PI HINDS, MONICA T, YIM, EVELYN KING FAI · 2016 to 2019
$2.6M
Microengineering the Dental Pulp Vascular Microenvironment_Diversity SupplementR01DE026170 · NIDCR · OREGON HEALTH & SCIENCE UNIVERSITY · PI BERTASSONI, LUIZ EDUARDO · 2016 to 2020
$2.5M
NHLBI NIH HHS R01 HL130274NIDCR NIH HHS R01 DE026170NIH HHS P51 OD011092
6 · The paper itself

Abstract

While clinical vascular grafting uses an end-to-side surgical method, researchers primarily use end-to-end implant techniques in preclinical models. This may be due in part to the limitations of using small animal models in research. The work presented here provides support and evidence for the improvement of vascular graft implant techniques by demonstrating the successful implantation of experimental grafts into both large and small animal models. Specifically, models of aortoiliac baboon (Papio anubis) bypass and common carotid rabbit (Oryctolagus cuniculus) bypass were used to test vascular grafts for thrombosis and vascular healing after 1 month using an end-to-side anastomosis grafting procedure. Patency was evaluated with ultrasound or histological techniques, and neointimal growth was quantified with histology. In the development of this procedure for small animals, both an end-to-end/end-to-side and an end-to-side/end-to-side configuration were tested in rabbits. One hundred percent of rabbit implants (2/2) with an end-to-end/end-to-side configuration were patent at explant. However, with the end-to-side/end-to-side configuration, 66% (6/9) of rabbit implants and 93% (13/14) of baboon implants remained patent at 1 month, suggesting the importance of replicating the end-to-side method for testing vascular grafts for clinical use. This study describes feasible preclinical surgical procedures, which simulate clinical vascular bypass grafts even in small animals. Widespread implementation of these end-to-side surgical techniques in these or other animals should improve the quality of experimental, preclinical testing and ultimately increase the likelihood of translating new vascular graft technologies into clinical applications.

Indexed as

AnimalsImplants, ExperimentalMaleModels, AnimalPapioRabbitsUltrasonography, DopplerVascular Graftinganastomosisanimal modelsendothelial cellssurgical techniquevascular graft

Identifiers

PMID29984616
PMCPMC6088253
OpenAlexW2847903436

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.