SynthesisPloS one2018
Interspinous process devices for treatment of degenerative lumbar spine stenosis: A systematic review and meta-analysis.
Synthesis in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 1 synthesis or guideline pooled it, 38 citations in OpenAlex.
- Clinical Evaluation of Surgery for Single-Segment Lumbar Spinal Stenosis: A Systematic Review and Bayesian Network Meta-Analysis.Orthopaedic surgery · 2022Pooled it
- Increasing adverse event reports coincide with declining Medicare billings for interspinous devices.North American Spine Society journal · 2026Article
- Standalone interspinous process devices for lumbar spinal stenosis: a critical literature review.BMC surgery · 2026Review
- The renewed role of interspinous devices: the InSpan system-a narrative review on surgical indications.Journal of spine surgery (Hong Kong) · 2026Review
- Demonstrating the feasibility of facet arthroplasty using the Total Posterior Spine System (TOPS) in the ambulatory surgery center (the TOPS outpatient experience).Journal of spine surgery (Hong Kong) · 2026Article
- Lumbar stand-alone interspinous fixation without decompression or bone graft: A 14-year cautionary case of late mechanical failure.Surgical neurology international · 2026Article
- Correlations of Lumbar Interspinous Distance with Neuroforaminal Dimensions, Disc Space Height, and Patient Demographic Factors.Tomography (Ann Arbor, Mich.) · 2025Article
- Readmission rates and hospital charges: a comparative study of surgical interventions in degenerative spondylolisthesis and spinal canal stenosis.Journal of orthopaedic surgery and research · 2025Article
- Analysis of 1027 Adverse Events Reports for Interspinous Process Devices From the US Food and Drug Administration Manufacturer and User Facility Device Experience Database.International journal of spine surgery · 2024Article
- Feasibility, safety, and efficacy of a new percutaneous interspinous device: a retrospective multicenter study.Neuroradiology · 2024Article
- Image-Guided Minimally Invasive Treatment Options for Degenerative Lumbar Spine Disease: A Practical Overview of Current Possibilities.Diagnostics (Basel, Switzerland) · 2024Review
- The Essence of Clinical Practice Guidelines for Lumbar Spinal Stenosis, 2021: 4. Surgical Treatment.Spine surgery and related research · 2023Article
- Biomechanical Evaluation of Transforaminal Lumbar Interbody Fusion with Coflex-F and Pedicle Screw Fixation: Finite Element Analysis of Static and Vibration Conditions.Orthopaedic surgery · 2022Article
- Analysis of Long-Term Results of Lumbar Discectomy With and Without an Interspinous Device.International journal of spine surgery · 2022Article
- Biomechanical comparison of different interspinous process devices in the treatment of lumbar spinal stenosis: a finite element analysis.BMC musculoskeletal disorders · 2022Article
- Interspinous Process Devices Do Not Reduce Intervertebral Foramina and Discs Heights on Adjacent Segments.Journal of pain research · 2022Article
- Article
- Degenerative Lumbar Spinal Stenosis.Revista brasileira de ortopedia · 2021Article
- Which is the most effective treatment for lumbar spinal stenosis: Decompression, fusion, or interspinous process device? A Bayesian network meta-analysis.Journal of orthopaedic translation · 2021Article
- Interlaminar stabilization offers greater biomechanical advantage compared to interspinous stabilization after lumbar decompression: a finite element analysis.Journal of orthopaedic surgery and research · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDegenerative lumbar spinal stenosis is a condition related to aging in which structural changes cause narrowing of the central canal and intervertebral foramen. It is currently the leading cause for spinal surgery in patients over 65 years. Interspinous process devices (IPDs) were introduced as a less invasive surgical alternative, but questions regarding safety, efficacy, and cost-effectiveness are still unanswered.
objectivesThe aim of this study was to provide complete and reliable information regarding benefits and harms of IPDs when compared to conservative treatment or decompression surgery and suggest directions for forthcoming RCTs.
methodsWe searched MEDLINE, EMBASE, Cochrane Library, Scopus, and LILACS for randomized and quasi-randomized trials, without language or period restrictions, comparing IPDs to conservative treatment or decompressive surgery in adults with symptomatic degenerative lumbar spine stenosis. Data extraction and analysis were conducted following the Cochrane Handbook. Primary outcomes were pain assessment, functional impairment, Zurich Claudication Questionnaire, and reoperation rates. Secondary outcomes were quality of life, complications, and cost-effectiveness. This systematic review was registered at Prospero (International prospective register of systematic reviews) under number 42015023604.
resultsThe search strategy resulted in 17 potentially eligible reports. At the end, nine reports were included and eight were excluded. Overall quality of evidence was low. One trial compared IPDs to conservative treatment: IPDs presented better pain, functional status, quality of life outcomes, and higher complication risk. Five trials compared IPDs to decompressive surgery: pain, functional status, and quality of life had similar outcomes. IPD implant presented a significantly higher risk of reoperation. We found low-quality evidence that IPDs resulted in similar outcomes when compared to standard decompression surgery. Primary and secondary outcomes were not measured in all studies and were often published in incomplete form. Subgroup analysis was not feasible. Difficulty in contacting authors may have prevented us of including data in quantitative analysis.
conclusionsPatients submitted to IPD implants had significantly higher rates of reoperation, with lower cost-effectiveness. Future trials should improve in design quality and data reporting, with longer follow-up periods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.