Evidence map›Paper›PMID 29978614›Full record

ArticleYonsei medical journal2018

CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model.

Seongpung Lee, Jun Young Kim, Jaesung Hong, Seung Hoon Baek, Shin Yoon Kim

Open access · goldAbstract read
In one paragraph

Article in Yonsei medical journal, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Seongpung LeeDepartment of Robotics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu, Korea.ORCID https://orcid.org/0000-0003-0488-8265
Jun Young KimDepartment of Orthopaedic Surgery, Daegu Catholic University College of Medicine, Daegu, Korea. dr.junyoung@gmail.com.ORCID https://orcid.org/0000-0003-4700-3041
Jaesung HongDepartment of Robotics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu, Korea.
Seung Hoon BaekDepartment of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, Korea.
Shin Yoon KimDepartment of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, Korea.
Daegu Gyeongbuk Institute of Science and Technology · KRKyungpook National University Hospital · KRDaegu Catholic University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe intraoperative version of the femoral component is usually determined by visual appraisal of the stem position relative to the distal femoral condylar axis. However, several studies have suggested that a surgeon's visual assessment of the stem position has a high probability of misinterpretation. We developed a computed tomography (CT)-based navigation system with a patient-specific instrument (PSI) capable of three-dimensional (3D) printing and investigated its accuracy and consistency in comparison to the conventional technique of visual assessment of the stem position. MATERIALS AND

methodsA CT scan of a femur sawbone model was performed, and pre-experimental planning was completed. We conducted 30 femoral neck osteotomies using the conventional technique and another 30 femoral neck osteotomies using the proposed technique. The femoral medullary canals were identified in both groups using a box chisel.

resultsFor the absolute deviation between the measured and planned values, the mean two-dimensional anteversions of the proposed and conventional techniques were 1.41° and 4.78°, while their mean 3D anteversions were 1.15° and 3.31°. The mean θ₁, θ₂, θ₃, and d, all of which are parameters for evaluating femoral neck osteotomy, were 2.93°, 1.96°, 5.29°, and 0.48 mm for the proposed technique and 4.26°, 3.17°, 4.43°, and 3.15 mm for the conventional technique, respectively.

conclusionThe CT-based navigation system with PSI was more accurate and consistent than the conventional technique for assessment of stem position. Therefore, it can be used to reduce the frequency of incorrect assessments of the stem position among surgeons and to help with accurate determination of stem anteversion.

Indexed as

Printing, Three-DimensionalTomography, X-Ray ComputedArthroplasty, Replacement, HipFemaleFemurFemur NeckHumansKnee JointMaleOsteotomySurgeonsSurgery, Computer-Assisted3D printingcomputer-assisted surgeryTotal hip replacement

Identifiers

PMID29978614
PMCPMC6037596
OpenAlexW2850627216

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.