Evidence map›Paper›PMID 29977326›Full record

ArticleComputational and mathematical methods in medicine2018

Method for Calculating the Bending Angle of Puncture Needle in Preoperative Planning for Transjugular Intrahepatic Portal Systemic Shunt (TIPS).

Xiaoli Zhu, Zhao Ran, Wanci Li, Wansheng Wang, Kangshun Zhu, Wensou Huang, Xin Gao

Open access · hybridAbstract read
In one paragraph

Article in Computational and mathematical methods in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 89% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Xiaoli ZhuInvasive Technology Department, The First Affiliated Hospital of Soochow University, No. 899, Pinghai Road, Suzhou, Jiangsu 215006, China.
Zhao RanDepartment of Medical Imaging, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou, Jiangsu 215163, China.
Wanci LiInvasive Technology Department, The First Affiliated Hospital of Soochow University, No. 899, Pinghai Road, Suzhou, Jiangsu 215006, China.
Wansheng WangInvasive Technology Department, The First Affiliated Hospital of Soochow University, No. 899, Pinghai Road, Suzhou, Jiangsu 215006, China.
Kangshun ZhuDepartment of Minimally Invasive Interventional Radiology, The Second Affiliated Hospital of Guangzhou Medical University, No. 250, Changgang East Road, Guangzhou, Guangdong 510260, China.ORCID 0000-0001-5142-010X
Wensou HuangDepartment of Minimally Invasive Interventional Radiology, The Second Affiliated Hospital of Guangzhou Medical University, No. 250, Changgang East Road, Guangzhou, Guangdong 510260, China.
Xin GaoDepartment of Medical Imaging, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou, Jiangsu 215163, China.ORCID 0000-0001-9906-0596
Soochow University · CNChinese Academy of Sciences · CNSecond Affiliated Hospital of Guangzhou Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transjugular Intrahepatic Portal Systemic Shunt is a comprehensive interventional therapy for portal hypertension. During this intervention, puncturing from hepatic vein into portal vein is a difficult step. Selecting puncture needle with a proper bending angle is vital to accurate puncture. Thus, this prospective study provides a method to calculate the angle of the puncture needle using preinterventional contrast-enhanced CT imaging. According to the geometrical characteristics of puncture needle, Bezier curve equation was adopted to describe its bending part. By testing whether each point in a specific region satisfied the equation set of Bezier curves, the possible position of needle tip was obtained. Then, the bending angle of puncture needle was obtained by calculating curvature. The method was evaluated in 13 patients from 2 centers showing now a success rate of 100% and a duration of the procedure of 141 and 161 minutes. The method based on Bezier curve equation for calculating a proper bending angle of puncture needle was proven to be effective. And the clinical study is preliminary and additional work for clinical evaluation is necessary.

Indexed as

Preoperative CareTomography, X-Ray ComputedAdultFemaleHepatic VeinsHumansMaleMiddle AgedPortal VeinPortasystemic Shunt, Transjugular IntrahepaticProspective StudiesPunctures

Identifiers

PMID29977326
PMCPMC5998197
OpenAlexW2807337375

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.