Evidence map›Paper›PMID 29970861›Full record

ArticleSensors (Basel, Switzerland)2018

Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing.

David Naranjo-Hernández, Alejandro Talaminos-Barroso, Javier Reina-Tosina, Laura M Roa, Gerardo Barbarov-Rostan, Pilar Cejudo-Ramos, Eduardo Márquez-Martín, Francisco Ortega-Ruiz

Registry-linked trialAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03832205 (Validation of a Capaciflector Against a Pneumotachometer to Measure Respiratory Rate and a Capaciflector Against Electrocardiography to Measure Heart Rate at Different Anatomical Chest Locations During Cardiopulmonary Exercise Testing), which is not on this map. Cited by 25 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03832205 completednot on this mapstarted 2019, after this paper: background citation

Validation of a Capaciflector Against a Pneumotachometer to Measure Respiratory Rate and a Capaciflector Against Electrocardiography to Measure Heart Rate at Different Anatomical Chest Locations During Cardiopulmonary Exercise Testing

TypeobservationalSponsorUniversity Hospital Southampton NHS Foundation TrustRan2019 to 2019Enrolled50ConditionsExercise, Respiratory Rate, Heart RateArmsCapaciflector monitoring
3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Observational
  9. Review
  10. Review
  11. Article
  12. Article
  13. A Sensor-Based mHealth Platform for Remote Monitoring and Intervention of Frailty Patients at Home.International journal of environmental research and public health · 2021
    Article
  14. Review
  15. Review
  16. Respiration Monitoring via Forcecardiography Sensors.Sensors (Basel, Switzerland) · 2021
    Article
  17. Article
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

David Naranjo-HernándezBiomedical Engineering Group, University of Seville, 41092 Seville, Spain. dnaranjo@us.es.ORCID 0000-0002-7636-2855
Alejandro Talaminos-BarrosoBiomedical Engineering Group, University of Seville, 41092 Seville, Spain. talaminos@gmail.com.ORCID 0000-0002-5047-5296
Javier Reina-TosinaBiomedical Engineering Group, University of Seville, 41092 Seville, Spain. jreina@us.es.ORCID 0000-0002-6853-4899
Laura M RoaBiomedical Engineering Group, University of Seville, 41092 Seville, Spain. lroa@us.es.ORCID 0000-0001-9221-0299
Gerardo Barbarov-RostanBiomedical Engineering Group, University of Seville, 41092 Seville, Spain. gbarbarov@gmail.com.ORCID 0000-0003-4383-9394
Pilar Cejudo-RamosMedical-Surgical Unit of Respiratory Diseases, University Hospital Virgen del Rocío, 41013 Seville, Spain. mariap.cejudo.sspa@juntadeandalucia.es.ORCID 0000-0003-0939-5427
Eduardo Márquez-MartínMedical-Surgical Unit of Respiratory Diseases, University Hospital Virgen del Rocío, 41013 Seville, Spain. eduardomarquezmartin@neumosur.net.
Francisco Ortega-RuizMedical-Surgical Unit of Respiratory Diseases, University Hospital Virgen del Rocío, 41013 Seville, Spain. francisco.ortega.sspa@juntadeandalucia.es.ORCID 0000-0003-1902-0522

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, a first approach to the design of a portable device for non-contact monitoring of respiratory rate by capacitive sensing is presented. The sensing system is integrated into a smart vest for an untethered, low-cost and comfortable breathing monitoring of Chronic Obstructive Pulmonary Disease (COPD) patients during the rest period between respiratory rehabilitation exercises at home. To provide an extensible solution to the remote monitoring using this sensor and other devices, the design and preliminary development of an e-Health platform based on the Internet of Medical Things (IoMT) paradigm is also presented. In order to validate the proposed solution, two quasi-experimental studies have been developed, comparing the estimations with respect to the golden standard. In a first study with healthy subjects, the mean value of the respiratory rate error, the standard deviation of the error and the correlation coefficient were 0.01 breaths per minute (bpm), 0.97 bpm and 0.995 (

Indexed as

Electric CapacitanceRespiratory RateWearable Electronic DevicesAdultFemaleHumansInternetMaleMonitoring, PhysiologicPulmonary Disease, Chronic Obstructivecapacitive sensingChronic Obstructive Pulmonary Disease (COPD)Internet of Medical Things (IoMT)respiratory raterespiratory rehabilitation

Identifiers

PMID29970861
PMCPMC6068602

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.