Evidence map›Paper›PMID 29958441›Full record

ArticleSensors (Basel, Switzerland)2018

Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots.

Renfeng Xue, Bingyin Ren, Jiaqing Huang, Zhiyuan Yan, Zhijiang Du

Abstract readValidation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Renfeng XueState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. xuerenfeng@hit.edu.cn.
Bingyin RenSchool of mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China. renby@hit.edu.cn.
Jiaqing HuangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. 17S008080@stu.hit.edu.cn.
Zhiyuan YanState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. yanzhiyuan@hit.edu.cn.
Zhijiang DuState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. duzj01@hit.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Due to the narrow space and a harsh chemical environment in the sterilization processes for the end-effector of surgical robots, it is difficult to install and integrate suitable sensors for the purpose of effective and precise force control. This paper presents an innovative tension sensor for estimation of grasping force in our laparoscope surgical robot. The proposed sensor measures the tension of cable using fiber gratings (FBGs) which are pasted in the grooves on the inclined cantilevers of the sensor. By exploiting the stain measurement characteristics of FBGs, the small deformation of the inclined cantilevers caused by the cable tension can be measured. The working principle and the sensor model are analyzed. Based on the sensor model, the dimensions of the sensor are designed and optimized. A dedicated experimental setup is established to calibrate and test the sensor. The results of experiments for estimation the grasping force validate the sensor.

Indexed as

Equipment DesignCalibrationLaparoscopesLaparoscopyRoboticsSterilizationSurgery, Computer-Assistedcable tensionforce sensormodelingsurgical robot

Identifiers

PMID29958441
PMCPMC6068875

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.