Observational studyEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2019
Active periodic electrograms in remote monitoring of pacemaker recipients: the PREMS study.
Observational study in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Improving Diagnostic Yield for Analyzing Periodic Electrograms in the Remote Detection of Pacemaker Lead Issues.Sensors (Basel, Switzerland) · 2025Observational
- [Telemedicine and ECG monitoring : Technical prerequisites and clinical workflow].Herzschrittmachertherapie & Elektrophysiologie · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsRemote monitoring (RM) is considered as a standard of care for pacemaker recipients. Remote monitoring systems provide calendar-based intracardiac electrogram recordings (IEGM) only with the current pacemaker settings (passive IEGM). PREMS (Pacemaker Remote Electrogram Monitoring Study), an observational, multicentre trial, prospectively evaluated the clinical value of an active IEGM (aIEGM), including three 10-s sections (passive IEGM, encouraged sensing, and encouraged pacing), compared to other RM data and to its passive IEGM section. Secondary objectives included the added value of the aIEGM to fully assess the sensing and pacing functions of each lead. METHODS AND
resultsPatients were enrolled within 3 months after pacemaker implantation and followed until the first transmitted aIEGM, which was analysed together with all other RM data. In total, 567 patients were enrolled (79 ± 9 years, 62% men, 19% single-chamber, and 81% dual-chamber pacemakers). Of 547 aIEGMs transmitted in 547 patients, 161 [29.4%; 95% confidence interval (95% CI) 25.6-33.3%] indicated at least one anomaly non-detectable with certainty-or at all-on other RM data, including atrial arrhythmia, extrasystoles, undersensing, oversensing, and loss of capture. In 21.7% of cases the detected events deserved a corrective action. The sensing and pacing function of each lead could be fully assessed in 77.3% of aIEGM (95% CI 72.6-82.0%) vs. 15.5% (95% CI 11.4-19.6%) when considering only the passive IEGM section (P < 0.001).
conclusionAn active IEGM improves the clinical value of remote pacemaker follow-up. Furthermore, compared to a passive IEGM, the aIEGM increases the capability to fully assess remotely the sensing and pacing functions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.