Evidence map›Paper›PMID 29948236›Full record

ArticleMagma (New York, N.Y.)2018

Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging.

Yuhong Peng, Chao Zou, Yangzi Qiao, Changjun Tie, Qian Wan, Rui Jiang, Chuanli Cheng, Dong Liang, Hairong Zheng, Faqi Li and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Magma (New York, N.Y.), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yuhong PengState Key Laboratory of Ultrasound Engineering in Medicine, Chongqing Key Laboratory of Biomedical Engineering, Co-Founded by Chongqing and the Ministry of Science and Technology, College of Biomedical Engineering, Chongqing Medical University, 153 Box, 1 Yixueyuan Road, Yuzhong District, Chongqing, 400016, China.
Chao ZouPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.ORCID http://orcid.org/0000-0002-6387-7809
Yangzi QiaoPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.
Changjun TiePaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.
Qian WanPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.
Rui JiangPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.
Chuanli ChengPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.
Dong LiangPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.
Hairong ZhengPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China.
Faqi LiState Key Laboratory of Ultrasound Engineering in Medicine, Chongqing Key Laboratory of Biomedical Engineering, Co-Founded by Chongqing and the Ministry of Science and Technology, College of Biomedical Engineering, Chongqing Medical University, 153 Box, 1 Yixueyuan Road, Yuzhong District, Chongqing, 400016, China. lifaqi70@163.com.
Xin LiuPaul C Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Blvd, Nanshan District, Shenzhen, 518055, Guangdong, China. xin.liu@siat.ac.cn.

Funding

Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province 2014B030301013National Natural Science Foundation of China 11504401National Natural Science Foundation of China 11574039National Natural Science Foundation of China 81327801National Natural Science Foundation of China 81527901Shenzhen Science and Technology Research Program JCYJ20150521094519487Shenzhen Science and Technology Research Program JCYJ20150630114942317
6 · The paper itself

Abstract

purposeReal-time monitoring is important for the safety and effectiveness of high-intensity focused ultrasound (HIFU) therapy. Magnetic resonance imaging is the preferred imaging modality for HIFU monitoring, with its unique capability of temperature imaging. For real-time temperature imaging, higher temporal resolution and larger spatial coverage are needed. In this study, a sequence based on the echo-shifted RF-spoiled gradient echo (GRE) with simultaneous multi-slice (SMS) imaging was designed for fast temperature imaging.

methodsA phantom experiment was conducted to evaluate the accuracy of the echo-shifted sequence using a fluorescent fiber thermometer as reference. The temperature uncertainty of the echo-shifted sequence was compared with the traditional GRE sequence at room temperature through the ex vivo porcine muscle. Finally, the ex vivo porcine liver tissue experiment using HIFU heating was performed to demonstrate that the spatial coverage was increased without decreasing temporal resolution.

resultsThe echo-shifted sequence had a better temperature uncertainty performance compared with the traditional GRE sequence with the same temporal resolution. The ex vivo heating experiment confirmed that by combining the SMS technique and echo-shifted sequence, the spatial coverage was increased without decreasing the temporal resolution while maintaining high temperature measurement precision.

conclusionThe proposed technique was validated as an effective real-time method for monitoring HIFU therapy.

Indexed as

AnimalsHigh-Intensity Focused Ultrasound AblationHot TemperatureHumansImage Processing, Computer-AssistedLiverMagnetic Resonance ImagingPhantoms, ImagingRadio WavesSwineThermometersThermometryEcho-shifted sequenceMagnetic resonance imagingSimultaneous multi-slice imagingThermometry

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.