Evidence map›Paper›PMID 29946975›Full record

ArticleJournal of materials science. Materials in medicine2018

Osseointegration evaluation of laser-deposited titanium dioxide nanoparticles on commercially pure titanium dental implants.

Zena G M Azzawi, Thekra I Hamad, Shehab A Kadhim, Ghassan Abdul-Hamid Naji

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Journal of materials science. Materials in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Advanced Nanostructured Coatings Based on Doped TiOMolecules (Basel, Switzerland) · 2023
    Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Biomedical Applications of TiOInternational journal of nanomedicine · 2020
    Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zena G M AzzawiMinistry of Health, Baghdad, Iraq. dr.zeena.ghazi@gmail.com.
Thekra I HamadDepartment of Prosthodontics, College of Dentistry, University of Baghdad, Bab-Almoadham, P.O. Box, 1417, Baghdad, Iraq.
Shehab A KadhimExpert, Laser and Optoelectronics Research Centre, Ministry of Science and Technology, Baghdad, Iraq.
Ghassan Abdul-Hamid NajiDepartment of Prosthodontics, College of Dentistry, University of Baghdad, Bab-Almoadham, P.O. Box, 1417, Baghdad, Iraq. dr_ghassan74@yahoo.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The nanotechnology field plays an important role in the improvement of dental implant surfaces. However, the different techniques used to coat these implants with nanostructured materials can differently affect cells, biomolecules and even ions at the nano scale level. The aim of this study is to evaluate and compare the structural, biomechanical and histological characterization of nano titania films produced by either modified laser or dip coating techniques on commercially pure titanium implant fixtures. Grade II commercially pure titanium rectangular samples measuring 35 × 12 × 0.25 mm length, width and thickness, respectively were coated with titania films using a modified laser deposition technique as the experimental group, while the control group was dip-coated with titania film. The crystallinity, surface roughness, histological feature, microstructures and removal torque values were investigated and compared between the groups. Compared with dip coating technique, the modified laser technique provided a higher quality thin coating film, with improved surface roughness values. For in vivo examinations, forty coated screw-designed dental implants were inserted into the tibia of 20 white New Zealand rabbits' bone. Biomechanical and histological evaluations were performed after 2 and 4 weeks of implantation. The histological findings showed a variation in the bone response around coated implants done with different coating techniques and different healing intervals. Modified laser-coated samples revealed a significant improvement in structure, surface roughness values, bone integration and bond strength at the bone-implant interface than dip-coated samples. Thus, this technique can be an alternative for coating titanium dental implants.

Indexed as

Dental ImplantsOsseointegrationTitaniumAnimalsCoated Materials, BiocompatibleImplants, ExperimentalLasersMaleMaterials TestingMetal NanoparticlesMicroscopy, Atomic ForceMicroscopy, Electron, ScanningRabbitsSurface PropertiesTibiaTorqueCoated Materials, BiocompatibleDental ImplantsTitaniumtitanium dioxide

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked