Evidence map›Paper›PMID 29946970›Full record

ArticleAnnals of biomedical engineering2018

In-Vitro Detection of Small Isolated Cartilage Defects: Intravascular Ultrasound Vs. Optical Coherence Tomography.

T Horeman, E C Buiter, B Pouran, M Stijntjes, J Dankelman, G J M Tuijthof

Abstract readComparative Study
In one paragraph

Article in Annals of biomedical engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Application of optical coherence tomography in clinical diagnosis.Journal of X-ray science and technology · 2019
    Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

T HoremanDepartment of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands. T.horeman@tudelft.nl.
E C BuiterDepartment of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands.
B PouranDepartment of Orthopaedics, UMC Utrecht Regenerative Medicine Centre, Utrecht, The Netherlands.
M StijntjesDepartment of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands.
J DankelmanDepartment of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands.
G J M TuijthofDepartment of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This experimental work focused on the sensor selection for the development of a needle-like instrument to treat small isolated cartilage defects with hydrogels. The aim was to identify the most accurate and sensitive imaging method to determine the location and size of defects compared to a gold standard (µCT). Only intravascular ultrasound imaging (IVUS) vs. optical coherent tomography (OCT) were looked at, as they fulfilled the criteria for integration in the needle design. An in-vitro study was conducted on six human cadaveric tali that were dissected and submerged in saline. To simulate the natural appearance of cartilage defects, three types of defects were created via a standardised protocol: osteochondral defects (OCD), chondral defects (CD) and cartilage surface fibrillation (CSF), all sized between 0.1 and 3 mm in diameter. The detection rate by two observers for all diameters of OCD were 80, 92 and 100% with IVUS, OCT and µCT, for CD these were 60, 83 and 97%, and for CSF 0, 29 and 24%. Both IVUS and OCT can detect the presence of OCD and CD accurately if they are larger than 2 mm in diameter, and OCT can detect fibrillated cartilage defects larger than 3 mm in diameter. A significant difference between OCT-µCT and IVUS-µCT was found for the diameter error (p = 0.004) and insertion depth error (p = 0.002), indicating that OCT gives values closer to reference µCT. The OCT imaging technique is more sensitive to various types and sizes of defects and has a smaller diameter, and is therefore preferred for the intended application.

Indexed as

CartilageHumansTomography, Optical CoherenceUltrasonography, InterventionalX-Ray MicrotomographyCatheter imagingIVUSNeedle interventionOCTOrthopedics(Osteo)chondral defects

Identifiers

PMID29946970
PMCPMC6208880

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.