Evidence map›Paper›PMID 29943180›Full record

ArticleEuropean radiology2019

Comparison between software volumetric breast density estimates in breast tomosynthesis and digital mammography images in a large public screening cohort.

Daniel Förnvik, Hannie Förnvik, Andreas Fieselmann, Kristina Lång, Hanna Sartor

Abstract readComparative Study
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Daniel FörnvikDepartment of Medical Imaging and Physiology, Skåne University Hospital, Medical Radiology Unit, Department of Translational Medicine, Lund University, Inga Marie Nilssons gata 49, 205 02, Malmö, Sweden.
Hannie FörnvikDepartment of Medical Imaging and Physiology, Skåne University Hospital, Medical Radiology Unit, Department of Translational Medicine, Lund University, Inga Marie Nilssons gata 49, 205 02, Malmö, Sweden.
Andreas FieselmannSiemens Healthcare GmbH, Forchheim, Germany.
Kristina LångDepartment of Medical Imaging and Physiology, Skåne University Hospital, Medical Radiology Unit, Department of Translational Medicine, Lund University, Inga Marie Nilssons gata 49, 205 02, Malmö, Sweden.
Hanna SartorDepartment of Medical Imaging and Physiology, Skåne University Hospital, Medical Radiology Unit, Department of Translational Medicine, Lund University, Inga Marie Nilssons gata 49, 205 02, Malmö, Sweden. hanna.sartor@med.lu.se.ORCID http://orcid.org/0000-0002-1116-5199

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare software estimates of volumetric breast density (VBD) based on breast tomosynthesis (BT) projections to those based on digital mammography (DM) images in a large screening cohort, the Malmö Breast Tomosynthesis Screening Trial (MBTST).

methodsDM and BT images of 9909 women (enrolled 2010-2015) were retrospectively analysed with prototype software to estimate VBD. Software calculation is based on a physics model of the image acquisition process and incorporates the effect of masking in DM based on accumulated dense tissue areas. VBD (continuously and categorically) was compared between BT [central projection (mediolateral oblique view (MLO)] and two-view DM, and with radiologists' BI-RADS density 4

resultsThere was a high correlation (r = 0.83) between VBD in DM and BT and substantial agreement between the software breast density categories [observed agreement, 61.3% and 84.8%; κ = 0.61 and ĸ = 0.69 for four (a/b/c/d) and two (fat involuted vs. dense) density categories, respectively]. There was moderate agreement between radiologists' BI-RADS scores and software density categories in DM (ĸ = 0.55) and BT (ĸ = 0.47).

conclusionsIn a large public screening setting, we report a substantial agreement between VBD in DM and BT using software with special focus on masking effect. This automated and objective mode of measuring VBD may be of value to radiologists and women when BT is used as the primary breast cancer screening modality. KEY POINTS: • There was a high correlation between continuous volumetric breast density in DM and BT. • There was substantial agreement between software breast density categories (four groups) in DM and BT; with clinically warranted binary software breast density categories, the agreement increased markedly. • There was moderate agreement between radiologists' BI-RADS scores and software breast density categories in DM and BT.

Indexed as

Breast DensitySoftwareBreastBreast NeoplasmsEarly Detection of CancerFemaleHumansMammographyMiddle AgedProspective StudiesROC CurveBreast neoplasmsDiagnostic imagingDigital breast tomosynthesisMammographyMass screening

Identifiers

PMID29943180
PMCPMC6291428

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.