Evidence map›Paper›PMID 29940068›Full record

ArticleBiotechnology and bioengineering2018

Resemblance of the human liver sinusoid in a fluidic device with biomedical and pharmaceutical applications.

Martí Ortega-Ribera, Anabel Fernández-Iglesias, Xavi Illa, Ana Moya, Víctor Molina, Raquel Maeso-Díaz, Constantino Fondevila, Carmen Peralta, Jaume Bosch, Rosa Villa and 1 more

Open access · hybridAbstract read
In one paragraph

Article in Biotechnology and bioengineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 46 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Mechanobiology of portal hypertension.JHEP reports : innovation in hepatology · 2023
    Review
  6. Review
  7. Article
  8. Review
  9. In Vitro Models for the Study of Liver Biology and Diseases: Advances and Limitations.Cellular and molecular gastroenterology and hepatology · 2023
    Review
  10. Review
  11. Review
  12. Role of liver sinusoidal endothelial cells in liver diseases.Nature reviews. Gastroenterology & hepatology · 2021
    Review
  13. Article
  14. Review
  15. Nuclear deformation mediates liver cell mechanosensing in cirrhosis.JHEP reports : innovation in hepatology · 2020
    Article
  16. Review
  17. Unraveling the transcriptional determinants of liver sinusoidal endothelial cell specialization.American journal of physiology. Gastrointestinal and liver physiology · 2020
    Article
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 3 countries.

Martí Ortega-RiberaLiver Vascular Biology Research Group, Barcelona Hepatic Hemodynamic Laboratory, IDIBAPS Biomedical Research Institute, Barcelona, Spain.ORCID 0000-0001-8647-7069
Anabel Fernández-IglesiasLiver Vascular Biology Research Group, Barcelona Hepatic Hemodynamic Laboratory, IDIBAPS Biomedical Research Institute, Barcelona, Spain.
Xavi IllaBiomedical Applications Group (GAB), Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Esfera UAB, Bellaterra, Spain.
Ana MoyaBiomedical Applications Group (GAB), Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Esfera UAB, Bellaterra, Spain.
Víctor MolinaLiver Surgery and Transplantation Unit, IDIBAPS, Hospital Clínic de Barcelona, Barcelona, Spain.
Raquel Maeso-DíazLiver Vascular Biology Research Group, Barcelona Hepatic Hemodynamic Laboratory, IDIBAPS Biomedical Research Institute, Barcelona, Spain.
Constantino FondevilaBiomedical Research Networking Center in Hepatic and Digestive Diseases (CIBEREHD), Madrid, Spain.
Carmen PeraltaBiomedical Research Networking Center in Hepatic and Digestive Diseases (CIBEREHD), Madrid, Spain.
Jaume BoschLiver Vascular Biology Research Group, Barcelona Hepatic Hemodynamic Laboratory, IDIBAPS Biomedical Research Institute, Barcelona, Spain.
Rosa VillaBiomedical Applications Group (GAB), Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Esfera UAB, Bellaterra, Spain.
Jordi Gracia-SanchoLiver Vascular Biology Research Group, Barcelona Hepatic Hemodynamic Laboratory, IDIBAPS Biomedical Research Institute, Barcelona, Spain.ORCID 0000-0001-7736-4089
Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine · ESCentro de Investigación Biomédica en Red · ESInstitut d'Investigacions Biomèdiques de Barcelona · ESUniversity Hospital of Bern · CHHospital Clínic de Barcelona · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Maintenance of the complex phenotype of primary hepatocytes in vitro represents a limitation for developing liver support systems and reliable tools for biomedical research and drug screening. We herein aimed at developing a biosystem able to preserve human and rodent hepatocytes phenotype in vitro based on the main characteristics of the liver sinusoid: unique cellular architecture, endothelial biodynamic stimulation, and parenchymal zonation. Primary hepatocytes and liver sinusoidal endothelial cells (LSEC) were isolated from control and cirrhotic human or control rat livers and cultured in conventional in vitro platforms or within our liver-resembling device. Hepatocytes phenotype, function, and response to hepatotoxic drugs were analyzed. Results evidenced that mimicking the in vivo sinusoidal environment within our biosystem, primary human and rat hepatocytes cocultured with functional LSEC maintained morphology and showed high albumin and urea production, enhanced cytochrome P450 family 3 subfamily A member 4 (CYP3A4) activity, and maintained expression of hepatocyte nuclear factor 4 alpha (hnf4α) and transporters, showing delayed hepatocyte dedifferentiation. In addition, differentiated hepatocytes cultured within this liver-resembling device responded to acute treatment with known hepatotoxic drugs significantly different from those seen in conventional culture platforms. In conclusion, this study describes a new bioengineered device that mimics the human sinusoid in vitro, representing a novel method to study liver diseases and toxicology.

Indexed as

CapillariesEndothelial CellsHepatocytesLab-On-A-Chip DevicesLiverAnimalsCoculture TechniquesHumansMaleRatsRats, Wistarhepatocyteliver-on-a-chipliver sinusoidal endothelial cellsLSECsinusoid

Identifiers

PMID29940068
PMCPMC6220781
OpenAlexW2809964367

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.