Evidence map›Paper›PMID 29930573›Full record

ArticleJornal vascular brasileiro

Gilberto do Nascimento Galego, Pierre Galvagni Silveira, Júlia Jochen Broering, Eduardo da Silva Eli, Marcelo Peixer Corbellini, Amir Antônio Martins de Oliveira

Open access · diamondAbstract read
In one paragraph

Article in Jornal vascular brasileiro. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Gilberto do Nascimento GalegoUniversidade Federal de Santa Catarina - UFSC, Departamento de Cirurgia, Florianópolis, SC, Brazil.
Pierre Galvagni SilveiraUniversidade Federal de Santa Catarina - UFSC, Departamento de Cirurgia, Florianópolis, SC, Brazil.
Júlia Jochen BroeringUniversidade Federal de Santa Catarina - UFSC, Departamento de Cirurgia, Florianópolis, SC, Brazil.
Eduardo da Silva EliUniversidade Federal de Santa Catarina - UFSC, Departamento de Cirurgia, Florianópolis, SC, Brazil.
Marcelo Peixer CorbelliniUniversidade Federal de Santa Catarina - UFSC, Departamento de Engenharia Mecânica, Florianópolis, SC, Brazil.
Amir Antônio Martins de OliveiraUniversidade Federal de Santa Catarina - UFSC, Departamento de Engenharia Mecânica, Florianópolis, SC, Brazil.
Universidade Federal de Santa Catarina · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPulmonary embolism is an important cause of cardiovascular death. Inferior vena cava filters have been shown to be effective for prevention of this condition.

objectivesTo determine the safety, performance and efficacy of a new inferior vena cava filter in an ovine model.

methodsBKone1 filters are self-centering with over-the-wire deployment, have three filtering regions and are made from nickel-titanium alloy. Eight of these filters were implanted in 8 sheep. The sheep were divided into 4 groups of two animals (A and B) and the number of clots injected differed by group. Two clots were injected in group 2, four in group 3, eight in group 4 and zero clots in group 1. A animals underwent euthanasia soon after the procedure and B animals were observed for 30 days and then euthanized after a control cavography. All inferior vena cavas were processed for histological examination. Clots were prepared in a metal mold, sectioned and then radiopaque markers were inserted. Clot capture was analyzed by identifying the radiopaque marker on fluoroscopy.

resultsNo clot migration was observed during follow-up. Control cavographies showed patent inferior vena cavas. Pathological examination indicated little inflammatory tissue response. All clots were captured in the condition with 2 clots, only one clot was missed in the group injected with 4 clots and in the condition of 8 clots, they were partly captured.

conclusionsThe filters were deployed safely. There was a reduction in efficacy as the number of blood clots increased.

Indexed as

in vivo modelovine modelpulmonary embolismvena cava filter

Identifiers

PMID29930573
PMCPMC5829702
OpenAlexW2402799370

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.