Evidence map›Paper›PMID 29924377›Full record

ArticleCardiology journal2019

The potential hazard of a non-slip element balloon causing distal longitudinal stent deformation: the first clinical experience and in vitro assessment.

Hiroki Shibutani, Yuzo Akita, Yohei Oishi, Hiroyuki Sueyoshi, Yu Mukai, Kotaro Yutaka, Yumie Matsui, Masahiro Yoshinaga, Masahiro Karakawa

Abstract readCase Reports
In one paragraph

Article in Cardiology journal, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Drug-Coated Balloon vs. Stent forFrontiers in cardiovascular medicine · 2021
    Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hiroki ShibutaniDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan. hs.vxvii@gmail.com.
Yuzo AkitaDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.
Yohei OishiDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.
Hiroyuki SueyoshiDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.
Yu MukaiDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.
Kotaro YutakaDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.
Yumie MatsuiDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.
Masahiro YoshinagaDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.
Masahiro KarakawaDivision of Cardiology, Osaka Saiseikai Izuo Hospital, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA new complication, longitudinal stent deformation (LSD), is increasingly reported with recent intracoronary stent designs. There have been experiences of unusual cases of distal LSD caused by entrapment of a Lacrosse® non-slip element (NSE) balloon (Goodman Co., Ltd., Nagoya, Japan), which has three flexible nylon elements to prevent slippage. Accordingly, the aim of this study is to report the clinical experience of distal LSD caused by the NSE in the documented center and to investigate the incidence and mechanisms involved.

methodsCoronary intervention cases were retrospectively reviewed using the NSE balloon in hospital between May 2014 and June 2017. In bench testing, distal LSD was reproduced in a silicon tube model to identify its mechanism.

resultsA total of 95 patients with 107 lesions underwent coronary interventions with NSE. Of these, 72 lesions (12 de-novo lesions and 60 in-stent restenosis) were treated using in-stent dilatation. Two distal LSD cases occurred, representing an incidence of 2.78% (2/72) among all procedures; 16.7% (2/12) of the de-novo lesions developed LSD. In vitro experimentation allowed indentification of the mechanisms involved and bailout strategies.

conclusionsThis is the first study to evaluate NSE balloon catheter entrapment complicated by distal LSD in which reconstruction of the deformed stent and retrieval of the NSE could be achieved successfully. There is a potential hazard for distal LSD during post-dilatation using the NSE balloon due to its structural characteristics. Careful assessment is needed to prevent this complication.

Indexed as

Cardiac CathetersDrug-Eluting StentsProsthesis FailureAgedAged, 80 and overAngioplasty, Balloon, CoronaryCoronary Artery DiseaseCoronary RestenosisDatabases, FactualFemaleHumansMaleMaterials TestingMiddle AgedModels, AnatomicProsthesis Designballoon angioplastycomplicationcoronary artery diseasedrug eluting stent

Identifiers

PMID29924377
PMCPMC8083032

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.