Evidence map›Paper›PMID 29923763›Full record

ArticleAmerican journal of physiology. Renal physiology2018

Novel hemodynamic structures in the human glomerulus.

Christopher R Neal, Kenton P Arkill, James S Bell, Kai B Betteridge, David O Bates, C Peter Winlove, Andrew H J Salmon, Steven J Harper

Registry-linked trialOpen access · bronzeAbstract read
In one paragraph

Article in American journal of physiology. Renal physiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05368766 (Predictive Value of Venous Excess Ultrasound Score in Management of Cardiorenal Patients), which is not on this map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05368766 unknown statusnot on this mapstarted 2022, after this paper: background citation

Predictive Value of Venous Excess Ultrasound Score in Management of Cardiorenal Patients

Typeobservational_patient_registrySponsorAssiut UniversityRan2022 to 2024Enrolled60ConditionsCardio-Renal SyndromeArmsVExUS score, Diuretic Effect
3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 41 citations in OpenAlex.

  1. Article
  2. Article
  3. Hemodynamic simulation andPhysics of fluids (Woodbury, N.Y. : 1994) · 2025
    Article
  4. Article
  5. Article
  6. Review
  7. Rational nanoparticle design: Optimization using insights from experiments and mathematical models.Journal of controlled release : official journal of the Controlled Release Society · 2023
    Review
  8. Article
  9. Article
  10. Article
  11. Mechanisms of vascular damage in ANCA vasculitis.Seminars in immunopathology · 2022
    Review
  12. Biomimetic models of the glomerulus.Nature reviews. Nephrology · 2022
    Review
  13. Review
  14. Review
  15. Article
  16. Review
  17. Article
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 2 countries.

Christopher R NealBristol Renal and School of Physiology, Pharmacology and Neuroscience, University of Bristol , Bristol , United Kingdom.
Kenton P ArkillDivision of Cancer and Stem Cells, School of Medicine, University of Nottingham, Queen's Medical Centre , Nottingham , United Kingdom.
James S BellCardiff Centre for Vision Science, Cardiff University , Cardiff , United Kingdom.ORCID 0000-0001-8371-9851
Kai B BetteridgeNikon Imaging Centre, Guys Campus, Kings College London , London , United Kingdom.
David O BatesDivision of Cancer and Stem Cells, School of Medicine, University of Nottingham, Queen's Medical Centre , Nottingham , United Kingdom.
C Peter WinloveSchool of Physics, University of Exeter , Exeter , United Kingdom.
Andrew H J SalmonWaitemata District Health Board , Auckland , New Zealand.
Steven J HarperBristol Renal and School of Physiology, Pharmacology and Neuroscience, University of Bristol , Bristol , United Kingdom.
University of Exeter · GBUniversity of Nottingham · GBCardiff University · GBKing's College London · GBUniversity of Bristol · GBWaitemata District Health Board · NZ

Funding

Medical Research Council G0802829Medical Research Council G10002073Medical Research Council G1002073
6 · The paper itself

Abstract

To investigate human glomerular structure under conditions of physiological perfusion, we have analyzed fresh and perfusion-fixed normal human glomeruli at physiological hydrostatic and oncotic pressures using serial resin section reconstruction, confocal, multiphoton, and electron microscope imaging. Afferent and efferent arterioles (21.5 ± 1.2 µm and 15.9 ± 1.2 µm diameter), recognized from vascular origins, lead into previously undescribed wider regions (43.2 ± 2.8 µm and 38.4 ± 4.9 µm diameter) we have termed vascular chambers (VCs) embedded in the mesangium of the vascular pole. Afferent VC (AVC) volume was 1.6-fold greater than efferent VC (EVC) volume. From the AVC, long nonbranching high-capacity conduit vessels ( n = 7) (Con; 15.9 ± 0.7 µm diameter) led to the glomerular edge, where branching was more frequent. Conduit vessels have fewer podocytes than filtration capillaries. VCs were confirmed in fixed and unfixed specimens with a layer of banded collagen identified in AVC walls by multiphoton and electron microscopy. Thirteen highly branched efferent first-order vessels (E1; 9.9 ± 0.4 µm diameter) converge on the EVC, draining into the efferent arteriole (15.9 ± 1.2 µm diameter). Banded collagen was scarce around EVCs. This previously undescribed branching topology does not conform to the branching of minimum energy expenditure (Murray's law), suggesting that even distribution of pressure/flow to the filtration capillaries is more important than maintaining the minimum work required for blood flow. We propose that AVCs act as plenum manifolds possibly aided by vortical flow in distributing and balancing blood flow/pressure to conduit vessels supplying glomerular lobules. These major adaptations to glomerular capillary structure could regulate hemodynamic pressure and flow in human glomerular capillaries.

Indexed as

HemodynamicsMicrocirculationRenal CirculationHumansHydrostatic PressureKidney GlomerulusMicroscopy, ConfocalMicroscopy, Electron, TransmissionMicroscopy, Fluorescence, MultiphotonMicrovesselsModels, BiologicalPodocytesTissue Fixationconduit vesselsglomerular microcirculationhemodynamicsmesangial collagenvascular chambers

Identifiers

PMID29923763
PMCPMC6293306
OpenAlexW2809596373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.