Evidence map›Paper›PMID 29923103›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2020

Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging.

Marvin Grossmann, Andreas A Giannopoulos, Fabiola A Bechtiger, Michael Messerli, Moritz Schwyzer, Dominik C Benz, Ken Kudura, Catherine Gebhard, Christoph Gräni, Aju P Pazhenkottil and 2 more

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Fully automated deep learning powered calcium scoring in patients undergoing myocardial perfusion imaging.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Trial
  3. Low-dose coronary artery calcium scoring compared to the standard protocol.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  4. Article
  5. Review
  6. Dose reduction is good but it is image quality that matters.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors.

Marvin GrossmannDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Andreas A GiannopoulosDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Fabiola A BechtigerDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Michael MesserliDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Moritz SchwyzerDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Dominik C BenzDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Ken KuduraDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Catherine GebhardDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Christoph GräniDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Aju P PazhenkottilDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Philipp A KaufmannDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Ronny R BuechelDepartment of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland. ronny.buechel@usz.ch.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe applicability of ultra-low-dose computed tomography (CT) for attenuation correction (AC) of single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) remains elusive. METHODS AND

resultsOne-hundred patients underwent one-day

conclusionsAttenuation maps for MPI obtained from ultra-low radiation dose CT scans are interchangeable with attenuation maps from standard-dose CT while offering a substantial reduction in radiation dose exposure.

Indexed as

Myocardial Perfusion ImagingTomography, Emission-Computed, Single-PhotonTomography, X-Ray ComputedAgedCadmiumFemaleHeart DiseasesHumansMaleMiddle AgedOrganophosphorus CompoundsOrganotechnetium CompoundsProspective StudiesRadiation DosageReproducibility of ResultsSensitivity and SpecificityCadmiumCdZnTeOrganophosphorus CompoundsOrganotechnetium Compoundstechnetium tc-99m tetrofosminTelluriumZincattenuation correctioncomputed tomographySPECTultra-low dose

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.