Evidence map›Paper›PMID 29921283›Full record

ArticleBiomedical engineering online2018

Estimation of the variations in mechanical impedance between the actuator and the chest, and the power delivered to the chest during cardiopulmonary resuscitation using machine-embedded sensors.

Seong Wook Choi, Do Yeon Lee, Kyoung Won Nam

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Seong Wook ChoiProgram of Mechanical & Biomedical Engineering, Kangwon National University, Chuncheon, South Korea.
Do Yeon LeeProgram of Mechanical & Biomedical Engineering, Kangwon National University, Chuncheon, South Korea.
Kyoung Won NamDivision of Biomedical Engineering, Pusan National University Yangsan Hospital, Yangsan, South Korea. marmera@gmail.com.ORCID http://orcid.org/0000-0002-8378-8758
Kangwon National University · KRPusan National University Yangsan Hospital · KR

Funding

Encouragement Program for The Industries of Economic Cooperation Region R0004491National Research Foundation of Korea C1013660-01-01
6 · The paper itself

Abstract

backgroundTo reduce the risk of patient damage and complications during the cardiopulmonary resuscitation (CPR) process in emergency situations, it is necessary to monitor the status of the patient and the quality of CPR while CPR processing without additional bio-signal measurement devices. In this study, an algorithm is proposed to estimate the mechanical impedance (MI) between an actuator of the CPR machine and the chest of the patient, and to estimate the power delivered to the chest of the patient during the CPR process.

methodsTwo sensors for force and depth measurement were embedded into a custom-made CPR machine and the algorithm for MI and power estimation was implemented. The performance of the algorithm was evaluated by comparing the results from the kinetic model, the conventional discrete Fourier transform (DFT), and the proposed method.

resultsThe estimations of the proposed method showed similar increasing/decreasing trends with the calculations from the kinetic model. In addition, the proposed method showed statistically equivalent performance in the MI estimation, and at the same time, showed statistically superior performance in the power estimation compared with the calculations from the conventional DFT. Furthermore, the MI and power estimation could be performed almost in real-time during the CPR process without excessive hands-off periods, and the intensity of random noise contained in the input signals did not seriously affect the MI and power estimations of the proposed method.

conclusionWe expect that the proposed algorithm can reduce various CPR-related complications and improve patient safety.

Indexed as

Mechanical PhenomenaThoraxAlgorithmsCardiopulmonary ResuscitationKineticsModels, BiologicalSafetyCardiopulmonary resuscitation machineChest compressionChest modelMechanical impedanceReal-time frequency analysis

Identifiers

PMID29921283
PMCPMC6011195
OpenAlexW2808959764

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.