Corneal epithelial permeability to fluorescein in humans by a multi-drop method.

Sangly P Srinivas, Arushi Goyal, Deepti P Talele, Sanjay Mahadik, Rachapalle Reddi Sudhir, P Pavani Murthy, Sudhir Ranganath, Uday B Kompella, Prema Padmanabhan

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2025
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Sangly P SrinivasSchool of Optometry, Indiana University, Bloomington, Indiana, United States of America.ORCID 0000-0002-7528-0735
Arushi GoyalDepartment of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.
Deepti P TaleleDepartment of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.
Sanjay MahadikDepartment of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.
Rachapalle Reddi SudhirDepartment of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.
P Pavani MurthyDepartment of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.
Sudhir RanganathDepartment of Chemical Engineering, Siddaganga Institute of Technology, Tumkur, India.
Uday B KompellaPharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, Colorado, United States of America.
Prema PadmanabhanDepartment of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.
Sankara Nethralaya · INIndiana University Bloomington · USSiddaganga Institute of Technology · INUniversity of Colorado Anschutz Medical Campus · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe permeability of the corneal epithelium to fluorescein Pdc is an indicator of the health of the ocular surface. It can be measured in a clinical setting by determining the accumulation of fluorescein in the stroma following administration of the dye on the ocular surface. Here we demonstrate a new multi-drop method for the measurement of Pdc by a spot fluorometer.

methodsTwenty-nine healthy participants were recruited for this study. First, a probe-drop of fluorescein (0.35%, 2 μL) was instilled on the conjunctiva. The clearance of the dye from the tears was immediately measured using the fluorometer. Following this, two loading drops (2%; 6 μL each) were administered 10 min apart. Fifteen minutes later, the ocular surface was washed and fluorescence from the stroma Fs was measured. Permeability was calculated using Pdc = (Q x Fs)/ (2 x AUC), where Q is the stromal thickness and AUC is the area under the fluorescence vs. time curve for the loading drops.

resultsAfter the probe drop, the tear fluorescence followed an exponential decay (elimination rate constant; kd = 0.41 ± 0.28 per min; 49 eyes of 29 subjects), but the increase in Fs was negligible. However, after the loading drops, the measured Fs was ~ 20-fold higher than the autofluorescence and could be recorded at a high signal to noise ratio (SNR > 40). The intra-subject variability of kd was insignificant. Since fluorescein undergoes concentration quenching at > 0.5%, the value of AUC for the loading drops was estimated by scaling the AUC of the probe drop. The calculated Pdc was 0.54 ± 0.54 nm/sec (n = 49). A Monte Carlo simulation of the model for the multi-drop protocol confirmed the robustness of the estimated Pdc.

conclusionsThe new multi-drop method can be used in place of the single-drop approach. It can overcome a lack of sensitivity in fluorometers of high axial resolution. The Pdc estimated by the multi-drop method is ~ 11-fold higher than previously reported but closer to the value reported for other drugs with equivalent octanol/water partition coefficient.

Indexed as

Administration, OphthalmicAdultComputer SimulationCorneal StromaEpithelium, CornealFemaleFluoresceinFluorescent DyesFluorometryHumansInstillation, DrugMaleMiddle AgedMonte Carlo MethodPermeabilityTearsFluoresceinFluorescent Dyes

Identifiers

PMID29920519
PMCPMC6007839
OpenAlexW2809239945

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.