Evidence map›Paper›PMID 29917093›Full record

ArticleNeurosurgery2019

Noninvasive Thermal Evaluation of Ventriculoperitoneal Shunt Patency and Cerebrospinal Fluid Flow Using a Flow Enhancing Device.

Mustafa Q Hameed, David Zurakowski, Mark R Proctor, Scellig S D Stone, Benjamin C Warf, Edward R Smith, Liliana C Goumnerova, Marek Swoboda, Tomer Anor, Joseph R Madsen

Abstract read
In one paragraph

Article in Neurosurgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Trial
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Mustafa Q HameedDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
David ZurakowskiDepartment of Anesthesiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
Mark R ProctorDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
Scellig S D StoneDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
Benjamin C WarfDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
Edward R SmithDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
Liliana C GoumnerovaDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
Marek SwobodaDrexel University, School of Biomedical Engineering, Science and Health Systems, Philadelphia, Pennsylvania.
Tomer AnorDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.
Joseph R MadsenDepartment of Neurosurgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.

Funding

Validation of ShuntCheck-Micro-Pumper, a non-invasive diagnostic procedure for deR44NS067772 · NINDS · NEURODX DEVELOPMENT, LLC · PI FRITZ, FREDERICK J, SWOBODA, MAREK · 2011 to 2013
$3.0M
NINDS NIH HHS R44 NS067772
6 · The paper itself

Abstract

backgroundWhile a noninvasive flow determination would be desirable in the diagnosis of cerebrospinal fluid shunt malfunction, existing studies have not yet defined a role for thermal flow detection.

objectiveTo evaluate a revised test protocol using a micropumper designed to transiently enhance flow during thermal testing to determine whether thermal detection of flow is associated with progression to shunt revision surgery.

methodsEighty-two unique tests were performed in 71 shunts. The primary outcome, need for revision within 7 d of testing, was compared with results of micropumper-augmented thermal flow detection. Statistical analysis was based on blind interpretation of test results and raw temperature data recorded during testing.

resultsThe test was sensitive (73%) and specific (68%) in predicting need for revision, with 5.6-fold higher probability of revision when flow was not detected. Negative predictive value in our sample was 94.2%. The probability of not requiring revision increased with increasing total temperature drop. Analysis of various possible thresholds showed that the optimal temperature cutoff may be lower than suggested by the manufacturer (0.125°C vs 0.2°C).

conclusionThis is the first study to report a strong association between thermal flow evaluation and a clinical impression that a shunt is not malfunctioning. The current recommended threshold may increase the false positive rate unnecessarily, and as clinicians gain experience with the method, they may find value in examining the temperature curves themselves. Multicenter studies are suggested to further define a role for this diagnostic test.

Indexed as

Equipment FailureVentriculoperitoneal ShuntDiagnostic Techniques, NeurologicalFemaleHumansMaleTemperatureCerebrospinal fluidHydrocephalusVentriculoperitoneal shuntVentriculoperitoneal shunt flowVentriculoperitoneal shunt malfunction

Identifiers

PMID29917093
PMCPMC12311973

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked