Comparison of Broadband and Discrete Wavelength Near-Infrared Spectroscopy Algorithms for the Detection of Cytochrome aa3 Reduction.
Article in Anesthesia and analgesia, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 4 citations in OpenAlex.
- Physiology, monitoring, and optimisation of perioperative tissue oxygenation: a narrative review.British journal of anaesthesia · 2026Review
- Quantification of cytochrome c oxidase and tissue oxygenation using CW-NIRS in a mouse cerebral cortex.Biomedical optics express · 2021Article
- Article
- Impact of inflammation on brain subcellular energetics in anesthetized rats.BMC neuroscience · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
backgroundCytochrome aa3, the terminal component of the electron transport chain, absorbs near-infrared radiation (NIR) differentially depending on its oxidation state (Cytox), which can in theory be measured using near-infrared spectroscopy (NIRS) by relating light absorption at specific wavelengths to chromophore concentrations. Some NIRS algorithms use discrete wavelengths, while others analyze a band of NIR (broadband NIRS). The purpose of this study was to test the ability of discrete wavelength and broadband algorithms to measure changes in Cytox (primary outcome), and to determine whether or not a discreet wavelength NIRS algorithm could perform similarly to a broadband NIRS algorithm for the measurement of Cytox in a staged hypoxia-cyanide model (hypoxia and cyanide have oppositional effects on tissue saturation, but both cause cytochrome reduction).
methodsTwenty Sprague-Dawley rats were anesthetized with isoflurane, intubated, and instrumented. Blood pressure, end-tidal carbon dioxide, and arterial oxygen saturation were measured. A halogen light source transmitted NIR transcranially. NIR from the light source and the skull was transmitted to 2 cooled charge-coupled device spectrometers. Rats were subjected to anoxia (fraction of inspired oxygen, 0.0) until arterial oxygen saturation decreased to 70%. After recovery, 5 mg/kg sodium cyanide was injected intravenously. The cycle was repeated until cardiac arrest occurred. Relative concentrations of hemoglobin and cytochrome aa3 were calculated using discreet wavelength and broadband NIRS algorithms.
resultsHypoxia led to an increase in calculated deoxyhemoglobin (0.20 arbitrary units [AUs]; 95% confidence interval [CI], 0.17-0.22; P < .0001), a decrease in calculated oxyhemoglobin (-0.16 AUs; 95% CI, -0.19 to -0.14; P < .0001), and a decrease in calculated Cytox (-0.057 AUs; 95% CI, -0.073 to 0.0040; P < .001). Cyanide led to a decrease in calculated deoxyhemoglobin (-0.037 AUs; 95% CI, 0.046 to -0.029; P < .001), an increase in calculated oxyhemoglobin (0.053 AUs; 95% CI, 0.040-0.065; P < .001), and a decrease in calculated Cytox (-0.056 AUs; 95% CI, -0.064 to -0.048; P < .001). The correlations between "discreet" wavelength algorithms (using 4, 6, 8, and 10 wavelengths) and the broadband algorithm for the measurement of calculated Cytox were 0.54 (95% CI, 0.52-0.56), 0.87 (0.87-0.88), 0.88 (0.88-0.89), and 0.95 (0.95-0.95), respectively.
conclusionsThe broadband and 10 wavelength algorithm were able to accurately track changes in Cytox for all experiments.