Evidence map›Paper›PMID 29915669›Full record

ArticleBiomedical physics & engineering express2017

Performance Comparison of Different Readouts for Position-Sensitive Solid-State Photomultiplier Arrays.

Junwei Du, Jeffrey P Schmall, Kun Di, Yongfeng Yang, Purushottam A Dokhale, Kanai S Shah, Simon R Cherry

Abstract read
In one paragraph

Article in Biomedical physics & engineering express, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. PET Detectors Based on Multi-Resolution SiPM Arrays.IEEE transactions on radiation and plasma medical sciences · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Junwei DuDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616, United States of America.
Jeffrey P SchmallDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616, United States of America.
Kun DiDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616, United States of America.
Yongfeng YangDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616, United States of America.
Purushottam A DokhaleRadiation Monitoring Devices Inc., Watertown, MA 02172, United States of America.
Kanai S ShahRadiation Monitoring Devices Inc., Watertown, MA 02172, United States of America.
Simon R CherryDepartment of Biomedical Engineering, University of California at Davis, Davis, CA 95616, United States of America.

Funding

Development of a Small Animal PET Scanner Using Solid State PhotomultipliersR01CA134632 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R, SHAH, KANAI · 2008 to 2012
$2.1M
Innovative Silicon Photomultiplier Technologies for Small-Animal PETR01EB019439 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R · 2015 to 2018
$1.4M
NCI NIH HHS R01 CA134632NIBIB NIH HHS R01 EB019439
6 · The paper itself

Abstract

A thorough comparison of five different readouts for reading out a 2 × 2 array of 5 mm × 5 mm position-sensitive solid-state photomultipliers (PS-SSPM) was undertaken. The five readouts include reading out the 20 signals (16 position and 4 timing) individually, two signal multiplexing readouts, and two position decoding readouts. Flood histogram quality, signal-to-noise ratio (SNR) and energy resolution were compared at different bias voltage (27.0 V to 32.0 V, at 0.5 V intervals) and at a fixed temperature of 0 °C by coupling a 6 × 6 array of 1.3 mm × 1.3 mm × 20 mm polished LSO crystals to the center of the PS-SSPM array. The timing resolution was measured at a bias voltage of 31.0 V (optimal bias voltage in terms of flood histogram quality). The best flood histogram quality value and signal-to-noise were 7.3 ± 1.6 and 33.5 ± 3.1, respectively, and were obtained by shaping and digitizing the 16 position signals individually. The capacitive charge-division readout is the simplest readout among the five evaluated but still resulted in good performance with a flood histogram quality value of 3.3 ± 0.4 and a SNR of 18.3 ± 1.3. The average energy resolution and the average timing resolution were 15.2 ± 1.2 % and 8.4 ± 1.6 ns for individual signal readout and 15.9 ± 1.2 % and 8.8 ± 1.3 ns by using the capacitive charge-division readout method. These studies show that for an ultra-high spatial resolution applications using the 2 × 2 PS-SSPM array, reading out the 20 signals individually is necessary; whilst the capacitive charge-division readout is a cost-effective readout for less demanding applications.

Indexed as

charge division readoutPETposition-sensitive solid-state photomultipliers

Identifiers

PMID29915669
PMCPMC6003720

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.